6GT2600-0AD10
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
• Material • PC
• Color • White/petrol
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +80 ℃
• During transportation and storage • -25 to +80 ℃
Degree of protection to EN 60529
• IP68
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810
1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810
1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85.6 x 54 x 0.9 mm
Weight 5 g
Type of mounting
• Fixing pocket
• Glued
1)
The values for shock and vibration are maximum values and must not be applied continuously.