User's Manual

Table Of Contents
ISO transponder
8.4 MDS D124
SIMATIC RF300
264 System Manual, 07/2016, C79000-G8976-C345-0x
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It i
s possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
8.4.4
Technical specifications
Table 8- 8 Technical specifications for MDS D124
6GT2600-0AC10
Product type designation
SIMATIC MDS D124
Memory
Memory configuration
UID 8 bytes
User memory 112 bytes EEPROM
OPT memory 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Material PPS
Color Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -25 to +180 ℃
from +125 ℃: 20% reduction in the limit dis-
tance
from +140 ℃: No processing possible