8.4.4
Technical specifications
Table 8- 8 Technical specifications for MDS D124
6GT2600-0AC10
Product type designation
SIMATIC MDS D124
Memory
Memory configuration
• UID • 8 bytes
• User memory • 112 bytes EEPROM
• OPT memory • 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
• Material • PPS
• Color • Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +180 ℃
• from +125 ℃: 20% reduction in the limit dis-
tance
• from +140 ℃: No processing possible