User's Manual
Table Of Contents
- 6 Antennas
- 7 RF300 transponder
- 7.1 Memory configuration of the RF300 transponders
- 7.2 SIMATIC RF320T
- 7.3 SIMATIC RF330T
- 7.4 SIMATIC RF340T
- 7.5 SIMATIC RF350T
- 7.6 SIMATIC RF360T
- 7.7 SIMATIC RF370T
- 7.8 SIMATIC RF380T
- 8 ISO transponder
ISO transponder
8.6 MDS D127
SIMATIC RF300
274 System Manual, 07/2016, C79000-G8976-C345-0x
8.6.4
Technical specifications
Table 8- 14 Technical specifications for MDS D127
6GT2600-0AF00
Product type designation
SIMATIC MDS D127
Memory
Memory configuration
• UID • 8 bytes
• User memory • 112 bytes EEPROM
• OPT memory • 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
• Material • PA6
• Color • Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +100 ℃
• During transportation and storage • -40 to +125 ℃
Degree of protection to EN 60529
• IP68
2 hours, 2 bar, +20 °C
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant to EN 60721-3-7 class 7M3
100 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3
20 g
1)
Torsion and bending load Not permitted