User's Manual
Table Of Contents
- 6 Antennas
- 7 RF300 transponder
- 7.1 Memory configuration of the RF300 transponders
- 7.2 SIMATIC RF320T
- 7.3 SIMATIC RF330T
- 7.4 SIMATIC RF340T
- 7.5 SIMATIC RF350T
- 7.6 SIMATIC RF360T
- 7.7 SIMATIC RF370T
- 7.8 SIMATIC RF380T
- 8 ISO transponder
ISO transponder
8.7 MDS D139
SIMATIC RF300
276 System Manual, 07/2016, C79000-G8976-C345-0x
8.7
MDS D139
8.7.1
Characteristics
MDS D139
Characteristics
Area of application Applications in production logistics and in assembly
lines subject to high temperatures (up to +220 °C)
Typical application areas:
• Paintshops and their preparatory treatments)
• Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
• Top coat area with drying furnaces
• Washing areas at temperatures > 85 °C
• Other applications with higher temperatures
Memory size 112 bytes of EEPROM user memory
Write/read range See section Field data of ISO transponders (MDS D)
(Page 52).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Note
Compatibility with SIMATIC RF300 depending on the article number
The transponder MDS D139 with article numbe
r 6GT2600-0AA10 is compatible with the
SIMATIC RF300 system. The transponder MDS D139 with article number 6GT2600
-0AA00
is not compatible.