User's Manual

Table Of Contents
ISO transponder
8.7 MDS D139
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
279
8.7.5
Technical specifications
Table 8- 17 Technical specifications for MDS D139
6GT2600-0AA10
Product type designation
SIMATIC MDS D139
Memory
Memory configuration
UID 8 bytes
User memory 112 bytes EEPROM
OPT memory 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Material PPS
Color Black
Recommended distance to metal
≥ 30 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -25 to +220 ℃
from +125 ℃: 20% reduction in the limit dis-
tance
from +140 ℃: No processing possible
at +200 ℃: Tested up to 5000 hours or
6000 cycles
at +220 ℃: Tested up to 2000 hours or
2000 cycles
During transportation and storage -40 to +100