286 System Manual, 07/2016, C79000-G8976-C345-0x
6GT2600-0AB10
Mechanical strength
• Isostatic pressure • 300 bar for 5 min
• Axial pressure • 1000 N for 10 s
• Radial pressure • 1000 N for 10 s
Resistance to chemicals All chemicals normally used in the washing pro-
cess
MDS lifespan
At least 100 wash cycles
Degree of protection
• IP68
24 hours, 2 bar, +20 °C
• IPx9K
Shock-resistant to IEC 68-2-27 40 g
1)
18 ms; 6 axes; 2000 repetitions/h
Vibration-resistant to IEC 68-2-6 10 g
1)
10 to 2000 Hz; 3 axes; 2.5 h
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
16 x 3 mm
Weight
1.2 g
Type of mounting
• Patched
• Sewn in
• Glued
1
The values for shock and vibration are maximum values and must not be applied continuously.
Note
Regeneration time between washing cycles
The regeneration time for the MDS D160 between washing cycles must be at least 24 ho
urs.