Readers 5.2 RF630R reader 5.2 RF630R reader 5.2.1 Description The SIMATIC RF630R is an active stationary reader in the UHF frequency range without an integrated antenna. Up to two external UHF RFID antennas can be connected via TNC reverse connections. The maximum HF power output is 0.5 W on the reader output. The SIMATIC RF630R is connected to a SIMATIC S7 controller via an ASM interface module. The degree of protection is IP65.
Readers 5.2 RF630R reader Highlights ● The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 2 and ISO/IEC 18000-6C standards ● Supports low-cost SmartLabels as well as reusable, rugged data media ● High reading speed: Depending on the function block (multitag mode), many tags can be detected simultaneously (bulk reading), rapidly moving tags are reliably acquired.
Readers 5.2 RF630R reader 5.2.1.2 Status display The device is equipped with a three colored LED. The LED can be lit in green, red or yellow. The meaning of the indication changes in accordance with the color and state (on, off, flashing) of the LED: Green LED Red LED Yellow LED Meaning Off Off Off The device is starting up. Flashing Off Off The device is ready. The antenna is switched off. On Off Off The device is ready. The antenna is switched on.
Readers 5.2 RF630R reader 5.2.1.3 Pin assignment of the RS422 interface Pin Pin Device end 8-pin M12 1 Assignment + 24 V 2 - Transmit 3 0V 4 + Transmit 5 + Receive 6 - Receive 7 Free 8 Earth (shield) The knurled bolt of the M12 plug is not connected to the shield (on the reader side). Note You must therefore not use any SIMATIC connecting cables that use the angled M12 plug.
Readers 5.2 RF630R reader 5.2.1.4 Pin assignment of the connecting cable Table 5- 6 M12 pin RS 422 - on reader side Core color Pin assignment 1 white 24 VDC 2 brown TX neg 3 green GND 4 yellow TX pos 5 Gray RX pos 6 pink RX neg 7 blue Not assigned 8 red Earth (shield) View of M12 connector Comment This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There are 8 color-coded single cores there for connecting to external devices.
Readers 5.2 RF630R reader 5.2.1.5 Grounding connection The RF620R/RF630R can be electrically connected to the ground potential through a contact washer. The tightening torque must be increased in this case to ensure that electrical contact is made (2.7 Nm). Ground connection (a) D E Hexagon-head screw (b) Plain washer (c) Cable lugs (d) Contact washer: Use contact washers according to the Siemens standard SN 70093-6-FSt-flNnnc480h for ground connection, Siemens item No.: H70093-A60-Z3 F G 5.2.
Readers 5.2 RF630R reader 5.2.2.2 Antenna/read point configurations You can connect up to two external antennas to the RF630R reader. The standard setting is that two antennas are connected when the reader is started. You have 3 possibilities for aligning the antennas and covering the read point. One RF630R reader with two antennas and two read points If you connect two external antennas to the device and align them in different directions, you can read tags at two different read points.
Readers 5.2 RF630R reader 5.2.3 Installing/Mounting 5.2.3.1 Mounting/Installation Requirement WARNING Ensure that the wall or ceiling can hold four times the total weight of the device. CAUTION Emitted radiation The transmitter complies with the requirements of Health Canada and the FCC limit values for subjecting persons to HF radiation, provided that a minimum spacing of 26 cm exists between antenna and person.
Readers 5.2 RF630R reader 5.2.4 Configuration/integration The RS422 system interface is provided for integrating the device into system environments/networks. The system interface transfers data to SIMATIC controllers or PCs with the appropriate interface. Apart from transmitting communication data from the reader to the controller and vice versa, the RS422 interface also supplies power to the reader (24 V DC).
Readers 5.2 RF630R reader 5.2.4.1 Transmission protocols RS 422 communication 3964R protocol Transmission rates 19.2 kbps 57.6 kbps 115.2 kbps Start bits 1 Data bits 8 Parity Odd Stop bits 1 5.2.5 Technical data 5.2.5.
Readers 5.2 RF630R reader Thermal and electrical properties MTBF (Mean Time Between Failures) 16 years Supply voltage • Permitted range 21.6 to 30 V DC 1 Supply voltage Current consumption Current consumption (in standby mode, no transmit power) (in standby mode, no transmit power) 20 V input voltage on the reader, typical 135 mA 2.7 W 24 V input voltage on the reader, typical 115 mA 2.76 W 30 V input voltage on the reader, typical 95 mA 2.
Readers 5.2 RF630R reader EMC & approvals for ETSI variant Electromagnetic compatibility ETSI EN 301 489-1 / -3 ETSI EN 302 208 Approvals • • • • • Radio to R&TTE- guidelines EN 300 330, EN 301 489 CE ETSI EN 302-208 V1.1.1 ETSI EN 302-208 V1.2.1 Reader degree of protection acc. to EN 60529 (IP65) EMC & approvals for FCC variant Electromagnetic compatibility FCC Part 15 Approvals • • • • • 5.2.5.2 FCC, cULus IEC60950, including US and Canadian variants of it FCC CFR47 Part 15.
Readers 5.2 RF630R reader Read distance for EU, EFTA, Turkey / China Antennas mounted on opposing sides (portal configuration) Antennas mounted on the same side max. 3.5 m (recommended maximum value for configuration) Max. 2 m (recommended maximum value for configuration; depending on the transponder) FCC frequencies North American frequency band 902 ... 928 MHz (50 channels, frequency hopping) Frequency band for China 920.125 to 924.875 MHz (16 subchannels at 2 W ERP, 20 subchannels at 0.
Readers 5.2 RF630R reader Dimension drawings 5.2.
Readers 5.2 RF630R reader 5.2.7 Certificates and approvals Table 5- 7 6GT2811-4AA00-0AA0 Certificate Designation CE approval according to R&TTE guideline Table 5- 8 6GT2811-4AA00-1AA0 Standard FCC CFR 47, Part 15 sections 15.247 Federal Communications Commission Industry Canada Radio Standards Specifications Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Readers 5.2 RF630R reader 5.2.7.1 FCC information Siemens SIMATIC RF630R (FCC): 6GT2811-4AA00-1AA0 FCC ID: NXW-RF630R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Readers 5.3 RF660R reader 5.3 RF660R reader 5.3.1 Description SIMATIC RF660R is a stationary reader for connecting up to 4 external antennas. A rugged housing with high IP65 degree of protection means that the device is a universal and reliable partner in harsh environments such as production plants, conveyor systems, warehouses, or direct at the loading gate.
Readers 5.3 RF660R reader 5.3.1.1 Ordering data Device Order No. RF660R reader basic unit for ETSI and FCC 6GT2811-0AA01 Accessories Description Order No. Antennas RF620A for ETSI (868 MHz) 6GT2812-1EA00 RF620A for FCC (915 MHz) 6GT2812-1EA01 RF660A for ETSI (868 MHz) 6GT2812-0AA00 RF660A for FCC (915 MHz) 6GT2812-0AA01 3 m (cable attenuation: 1.0 dB) 6GT2815-0BH30 10 m (cable attenuation: 2.0dB) 6GT2815-1BN10 10 m (cable attenuation: 4.0dB) 6GT2815-0BN10 20 m (cable attenuation: 4.
Readers 5.3 RF660R reader 5.3.1.
Readers 5.3 RF660R reader 5.3.1.3 Status displays Status displays LEDs Color Description Power on Green Power supply ON Tag Detect Yellow LED lit, as soon as at least one tag with a correct tag ID is within the field. System error Red Reader is not active, a more or less major fault has occurred In addition, this LED also indicates the fault status through the number of flashing pulses. Reboot (operating voltage Off → On is necessary).
Readers 5.3 RF660R reader 5.3.1.4 Pin assignment of the serial interfaces RS 232 connector (on reader side) Pin assignment 1 2 3 4 5 RS232_TX N.C. N.C. RS232_RX GND Pin Pin assignment 1 2 3 4 5 6 7 8 Transmit Data (+) Transmit Data (-) Receive Data (+) Terminated Terminated Receive Data (-) Terminated Terminated Industrial Ethernet (on reader side) Pin NOTICE We recommend that only original Siemens Ethernet connectors are used (10 m cable: Order No.
Readers 5.3 RF660R reader 5.3.1.5 Pin assignment and connections of the digital I/O interface Pin assignment Digital I/O socket (on reader side) Pin Pin assignment 1 2 3 4 5 6 7 8 Input USER_IN (0) Input USER_IN (1) Input USER_IN (2) GND (IN) Output USER_OUT (0) Output USER_OUT (1) Output USER_OUT (2) Housing Connections 5) 5 'LJLWDO , 2 9 3LQ 86(5B,1B 3LQ 86(5B,1B 3LQ 86(5B,1B 3LQ *1' 9 3RZHU 6XSSO\ 3LQ 86(5B287B 3LQ 86(5B287B 3LQ 86(5
Readers 5.3 RF660R reader Input USER_IN (0), (1), (2) ● The inputs are optically isolated through optocouplers. ● The 24 V voltage for the digital inputs (e.g. switches, proximity switches) must be supplied over a separate cable. ● The 24 V voltage for the digital inputs can alternatively be supplied from a digital output (USER-OUT). In the user program, however, the digital output must be permanently connected to "1" in this case.
Readers 5.3 RF660R reader 5.3.1.
Readers 5.3 RF660R reader 5.3.1.7 Power supply Pin assignment of the power connections Power connector (on reader side) 5.3.1.8 Pin Pin assignment 1 2 3 4 Ground (0 V) +24 V +24 V Ground (0 V) Grounding connection A low-impedance earth connection ensures that interference signals generated, for example, by external power supply cables or signal cables are safely discharged to earth.
Readers 5.3 RF660R reader 5.3.2 Planning application Firmware and software compatibility CAUTION Damage to the reader The SIMATIC RF660R reader with firmware version V1.2 must only be configured and operated with the relevant SIMATIC RF660R Configuration Software V1.2. The SIMATIC RF660R reader with firmware version V1.3 must only be configured and operated with the relevant SIMATIC RF660R Configuration Software V1.2 (limited functionality) or V1.3.
Readers 5.3 RF660R reader 5.3.2.1 Increasing the probability of identification for tags - Antenna switching To achieve a high probability of reading tags, the antenna switching function has been implemented in the RF660R reader: During a defined time period, the reader transmits on one antenna and receives on the other. As long as the antenna is receiving signals from further tags, the reader continues to transmit on the same transmitter antenna until all responding tags have been identified.
Readers 5.3 RF660R reader 5.3.3 Installation /Mounting Requirement WARNING Ensure that the wall or ceiling can hold four times the total weight of the device. CAUTION Emitted radiation The transmitter complies with the requirements of Health Canada and the FCC limit values for subjecting persons to HF radiation, provided that a minimum spacing of 26 cm exists between antenna and person.
Readers 5.3 RF660R reader 5.3.3.1 Configuration/integration Configuration Two communication interfaces are available for integrating the device into system environments/networks: ● Ethernet and ● RS 232 The communication interfaces transfer the data to IT, ERP and SCM systems on SIMATIC PLCs or PCs (also used for configuration and diagnostics). Simple process controls (e.g. a traffic signal) can be directly implemented using the write/read device via three digital inputs and outputs with 24 V each.
Readers 5.3 RF660R reader Transmission protocols RS232 communication XML protocol Transmission rates 115200 bps Start bits 1 Data bits 8 Parity None Flow control Xon/Xoff Stop bits 1 Ethernet communication The Ethernet interface offers automatic selection between 10BaseT and 100BaseTX. Shielded Twisted-Pair patch cables with standard RJ45 connectors are recommended for a reliable connection.
Readers 5.3 RF660R reader 5.3.4 Technical specifications 5.3.4.1 Mechanical data Mechanical specification of RF660R Weight 3.7 kg Dimensions (L x W x H) in mm 320 x 145 x 100 without connections Material Aluminum Color Anthracite MTBF (Mean Time Before Failure) 27,2 years Power consumption, typical 24 V • At 2 W transmit power • No digital outputs active 800 mA Mechanical environmental conditions Shock ETSI EN 300 019-2-3 V2.1.2 IEC 60068-2-27 Total shock response spectrum Type 3.
Readers 5.3 RF660R reader Status displays on the device Power On Green LED Tag Detect Yellow LED System error Red LED Interfaces Antenna connections 4x RTNC connector Maximum number of antenna channels operating independently of each other 2 (with 2 x 2 antennas, tags can be read by a reader at 2 independent locations) Ethernet 10BaseT or 100BaseTx 1x RJ45 connection according to IEEE 802.3 and ISO 8802-3 RS422 Currently unassigned RS232 1x connector (5-pin M12).
Readers 5.3 RF660R reader 5.3.4.2 Technical data according to EPC and ISO Frequencies European frequency band 865 … 868 MHz (4 channels 865.7 MHz; 866.3 MHz; 866.9 MHz; 867.5 MHz without LBT with up to 2 W ERP) North American frequency band 902 ... 928 MHz (50 channels, frequency hopping) Frequency band for China 920.125 to 924.875 MHz (16 subchannels at 2 W ERP, 20 subchannels at 0.1 W ERP) Frequency accuracy max.
Readers 5.3 RF660R reader Dimension drawings 5.3.
Readers 5.3 RF660R reader 5.3.6 Certificates and approvals 5.3.6.1 CE mark Table 5- 11 6GT2811-0AA01 Certificate Description CE approval according to R&TTE guideline Table 5- 12 FCC IDs: NXW-RF660; IC: 267X-RF660 Standards FCC Title 47, Part 15.sections 15.247 Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Readers 5.3 RF660R reader 5.3.6.2 FCC information Siemens SIMATIC RF660R FCC ID: NXW-RF660 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.