© Siemens AG 2012 Photovoltaics SINVERT PVS 600Series Central Inverters and Components for Photovoltaic Power Plants Brochure · April 2012 SINVERT Answers for the environment.
© Siemens AG 2012 Sunny prospects for photovoltaic plants The SINVERT PVS 600Series central inverters from 500 to 2 520 kW: compact, robust, durable Whether on the roofs of large industrial facilities, in ground-mounted PV systems, or solar power plants – you can now utilize the power of the sun even more efficiently: with the new three-phase SINVERT PVS 600Series photovoltaic inverters. With these inverters you can achieve a peak efficiency of 98.7% and a European efficiency of 98.
© Siemens AG 2012 Contents text Introduction Sunny prospects for photovoltaic plants . . . . . . . . . . . 2 SINVERT PVS 600Series central inverters . . . . . . . . . 4 Features and advantages at a glance. . . . . . . . . . . . . . 4 Technical data of the PVS500 (IEC) . . . . . . . . . . . . . . . 6 Technical data of the PVS585 (IEC) . . . . . . . . . . . . . . . 7 Technical data of the PVS600 (IEC) . . . . . . . . . . . . . . . 8 Technical data of the PVS630 (IEC) . . . . . . . . . . . . . . .
© Siemens AG 2012 SINVERT PVS 600Series central inverters Features and advantages at a glance Transformerless, 3-phase SINVERT PVS inverters are reliable, grid-compatible and cost-effective photovoltaic inverters which are used to convert solar energy into grid-compliant AC voltage for feeding into conventional power grids – thereby achieving peak efficiency levels of up to 98.7%.
© Siemens AG 2012 SINVERT PVS 600Series Inverter type Power / kW 500 1000 1500 2000 PVS500 PVS585 PVS600 PVS630 PVS1000 PVS1170 PVS1200 PVS1260 PVS1500 PVS1755 PVS1800 PVS1890 PVS2000 PVS2340 PVS2400 PVS2520 Power levels of the SINVERT PVS 600Series central inverters SINVERT PVS 600Series central inverter (subunit) SINVERT PVS 600Series central inverters 5
© Siemens AG 2012 Technical data of the SINVERT PVS500 inverter (according to IEC)1) Inverter type PVS500 PVS1000 PVS1500 PVS2000 V 450 ... 750 450 ... 750 450 ... 750 450 ...
© Siemens AG 2012 Technical data of the SINVERT PVS585 inverter (according to IEC)1) Inverter type PVS585 PVS1170 PVS1755 PVS2340 V 530 ... 750 530 ... 750 530 ... 750 530 ...
© Siemens AG 2012 Technical data of the SINVERT PVS600 inverter (according to IEC)1) Inverter type PVS600 PVS1200 PVS1800 PVS2400 V 570 ... 750 570 ... 750 570 ... 750 570 ...
© Siemens AG 2012 Technical data of the SINVERT PVS630 inverter (according to IEC)1) Inverter type PVS630 PVS1260 PVS1890 PVS2520 V 570 ... 750 570 ... 750 570 ... 750 570 ...
© Siemens AG 2012 Options for SINVERT PVS 600Series inverters Basic versions and options 1 000 V option The SINVERT PVS 600Series of inverters can be adapted and expanded by means of options in order to meet the individual needs of the plant. The 1 000 V option increases the maximum permissible input voltage of the SINVERT PVS inverter from 820 to 1 000 V.
© Siemens AG 2012 SINVERT PVS inverters for industrial roof systems A SINVERT PVS2000 is used for the Aspropyrgos 2 MW roof system erected in Greece in 2011 for Big Solar SINVERT PVS inverters for solar power plants The 31 MW solar power plant at Les Mées in France was constructed in 2010/2011 for Eco Delta and connected to the grid in August 2011.
© Siemens AG 2012 SINVERT PVS in power plants Link between solar power and public AC grid How solar power is fed into the AC grid Sunlight is transformed into solar energy in the photovoltaic modules. The direct current obtained is bundled in the field with the aid of SINVERT PVS CombinerBoxes and then fed into a SINVERT PVS inverter (see diagrams on this page).
© Siemens AG 2012 The SINVERT PVS CombinerBoxes are designed for vertical mounting. The output side of the SINVERT PVS CombinerBoxes can be optionally equipped with or without a switch disconnector. CombinerBoxes with switch disconnectors are capable of disconnecting the connected section of the photovoltaic generator from the SINVERT PVS inverter, e.g. for maintenance work.
© Siemens AG 2012 IEC-compliant inverter stations The inverter stations are system solutions for fast, simple implementation of turnkey photovoltaic stations. They are ideally suited for photovoltaic power plants ("Power Plant" segment) with outputs of 1 000 kW upwards. They are typically employed in ground-mounted systems. Inverter stations contain two to four SINVERT PVS inverters and, depending on the selected type, also medium-voltage switchgear and medium-voltage transformers.
© Siemens AG 2012 Intensity of solar irradiation morning noon evening night 1st day 2nd day RE10_00034 3rd day 4th day The inverters integrated in the inverter stations operate with a rotating master according to the master-slave principle. The diagram shows in simplified form that the master moves to the next inverter each day (see left column). In actual fact, the inverter with the fewest operating hours is started as the master on the next day.
© Siemens AG 2012 Establishing communication with PVS and system components Communication via Industrial Ethernet and plant monitoring with WinCC Internet Industrial Ethernet SCALANCE S VPN Router DSL-Router WinCC WebNavigator Inverter - Stations 2-n Inverter - Station 1 Inverter SINVERT PVS Inverter SINVERT PVS SINVERT PVS WeatherStation 200 WinCC PC SINVERT PVS ComBox 100 SINVERT PVS ComBox 100 Weather sensors Industrial Ethernet FOC ring Circle control receiver EVU 0% SINVERT PVS ControlBo
© Siemens AG 2012 Regulation of the PV plant according to BDEW Guideline and the current amendment of the Renewable Energy Act (EEG) by means of SINVERT PVS ControlBox 300 displayed with WinCC The "Generating Plants in the Medium-Voltage Grid" BDEW guideline stipulates this requirement for all systems feeding in at the medium-voltage level. Its primary benefit is that it enables grid operators to limit the output of the plant by remote means in accordance with § 6 of the Renewable Energy Act 2009.
© Siemens AG 2012 Communication via Industrial Ethernet and plant monitoring by means of SINVERT WebMonitor Internet Industrial Ethernet SCALANCE S VPN Router Inverter - Station 1 DSL-Router SINVERT WebMonitor Inverter - Stations 2-n Inverter SINVERT PVS Inverter SINVERT PVS Client SINVERT PVS WeatherStation 200 SINVERT PVS ComBox 200 SINVERT PVS ComBox 100 Weather sensors Industrial Ethernet FOC ring RE10_00033d Integration of SINVERT PVS inverters into a photovoltaic plant without solar PV plan
© Siemens AG 2012 SINVERT puts sunshine into the grid. Worldwide.
© Siemens AG 2012 PV plant dimensioning with SINVERT Select For fast and easy dimensioning The key features of SINVERT Select are: ■ The structure and workflow of the SINVERT Select program means that photovoltaic plants containing SINVERT inverters can be dimensioned quickly and simply in just a few steps. ■ The SINVERT Select program can be operated intuitively thanks to the clear structure of the graphical user interface.
© Siemens AG 2012 PV plant monitoring For an instant, up-to-date overview and rapid intervention PV plant monitoring with WinCC The key features of WinCC are: ■ A clearly designed user interface provides an instant overview of all key data of the managed plants, subplants and inverters, e.g.
© Siemens AG 2012 PV plant monitoring with SINVERT WebMonitor The key features of SINVERT WebMonitor are: SINVERT WebMonitor for monitoring photovoltaic plants ■ Clear user interface layout provides a quick overview of managed plants, subplants and inverters in a tree structure. ■ Overview page (dashboard) and plant page provide instant, up-to-date information about all key aspects of the plants, subplants and inverters, e.g. states, energy production (daily energy, total energy) and income.
© Siemens AG 2012 Selection and ordering data for devices and accessories SINVERT PVS 600Series inverters Product type identification Number of masters/slaves Active power output (rated value) Output voltage (rated value) MPP voltage Input voltage (max. permissible) kW V V V Order No. SINVERT PVS inverters (IEC-compliant) Grid frequency 50Hz (rated value) PVS500 1M 500 288 450 ... 750 820 6AG3111-1AH00-3AB0 PVS585 1M 585 340 530 ...
© Siemens AG 2012 Options for SINVERT PVS 600Series inverters When ordering an inverter, the order numbers of the respective option are added to the order number of the basic version, i.e. if all four possible options are utilized, five order numbers must be specified for ordering the inverter concerned. The number of slaves of the respective SINVERT PVS 600Series inverters is to be specified by the 11th digit of the order numbers of the inverters and of the associated options.
© Siemens AG 2012 System components, accessories, spare parts for SINVERT PVS 600Series inverters Product type identification Number of inputs Type of fuse protection at input Input current per input (maximum) Isolating device at the output Surge arrester Order No.
© Siemens AG 2012 Service & Support Unique range of complete services for the entire life cycle rt up p o S e n O n li ld Fie vice r Se Service Programs Modernization Services The range of services offered by Siemens Industry Automation and Drive Technologies includes comprehensive Service and Support for a very broad range of users.
© Siemens AG 2012 Training Extend your competitive edge – with practical know-how directly from the manufacturer. Familiarize yourself with the technical details and advantages of SINVERT solar inverters so that you can work out the best plant configuration for any situation. www.siemens.com/sinvert/ training Advantages at a glance: Service programs Our service programs comprise selected packages of services for photovoltaic plants.
© Siemens AG 2012 Tailored program of services for SINVERT PVS Spare parts service Service calls Security of supply of necessary spares - without contractual obligations Service specialists assure plant availability The spare parts service for SINVERT PVS offers you two ways of ordering spares: – On-demand spare parts delivery – SparesKits Three different types of service call are available: – Commissioning – On-site service – Maintenance On-demand spare parts delivery Service calls for SINVERT PVS
© Siemens AG 2012 Service contracts SINVERT PVS service contracts can be concluded within the first 24 months following commissioning of the installation. Depending on the contract type, a contract term of 10, 15 or 20 years can be selected. 24h Service contracts for SINVERT PVS inverters New: 24/7 hotline for contract customers The sales contact person in the respective region must be contacted for specific orders: www.siemens.com/sinvert/partner SINVERT PVS service contracts safeguard investments.
© Siemens AG 2012 SINVERT PVS SparesContract – Spares stocking as a low-cost alternative spare part requirements. Any spare parts required shall be taken from the spares kit and replacement parts then ordered free of charge from Siemens. All repair and maintenance work shall be carried out by the customer's own trained service personnel. In the event that on-site troubleshooting support by a Siemens specialist is required, a service call must be ordered separately.
© Siemens AG 2012 SINVERT PVS MaintenanceContract – Routine maintenance by Siemens The SINVERT PVS FullServiceContract can be selected with a contract term of 10, 15 or 20 years depending on the individual requirements of the customer. SINVERT PVS MaintenanceContract SINVERT PVS FullServiceContract The SINVERT PVS MaintenanceContract ensures that routine maintenance is provided by Siemens specialists.
© Siemens AG 2012 Get more information: Technical Assistance Phone: +49 (911) 895-5900 Fax: +49 (911) 895-5907 E-mail: technical-assistance@siemens.com Siemens AG Industry Sector Control Components and Systems Engineering Postfach 2355 90713 FÜRTH GERMANY www.siemens.com/sinvert Subject to change without notice Order No.: E86060-T1818-A101-A2-7600 MP.R3.XT.0000.00.2.07 / Dispo 46371 BR 0512 3.