Operating instructions

2
EF4100 Overall Dimensions
Figure 2
Provide adequate clearances around air openings into the
combustion chamber and adequate accessibility clearance for
servicing and proper operation. Never obstruct the front
opening of the heater.
The heater may be installed as a free-standing unit mount-
ed on a noncombustible protective floor pad or hearth, or it
may be mounted into an existing U. L. approved wood stove
chimney using a Hearth Extension (p/n 11099). Non-combu-
stible floor protection is required and must be used when
placing the heater on any combustible material.
The pellet heater must be operated with a power source
and will not operate using natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, the heater will automatically switch to 12 volt
power. An optional backup battery is available for the unit
which lasts approximately 48 hrs on high and 72 hrs on low.
A bigger battery may be purchased if desired for longer
durations.
The EasyFire Pellet Heater has been listed by OMNI-Test
Laboratories, Inc. to ASTM, U.L.,and EPA Standards.
CAUTION: Do not connect this unit to a chimney flue serving
another appliance.
Use only listed Type "L" pellet vent or stainless liner and
components for installation. Failure to use listed components
will void your warranty. See pipe manufacturer instructions for
installation instructions.
OUTSIDE COMBUSTION AIR IS MANDATORY IN
MOBILE OR MODULAR HOME INSTALLATIONS. SEE
SECTION ON OUTSIDE AIR INSTALLATION.
CAUTION: DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
INSTALLATION INSTRUCTIONS
Check with local building officials for specific code
requirements.
A listed, type "L" Pellet Vent Pipe or Stainless Liner is
MANDATORY on all installations.
WARNING: Installation of a Mobile Attachment Home
Kit P/N 10412 and outside combustion air is mandatory
in mobile or modular home installations although it may
also be used in all residential applications.
An outside air inlet MUST be provided for
combustion and ventilation air. The air inlet must
remain unrestricted while unit is in use. Outside air
connection is located in the rear of the heater (Figure 1).
NOTE: Vent Pipes’ inner diameters may vary.
For Vent Pipes Ø3.00" or smaller, use SPI Exhaust Vent
Adapter p/n 11076.
This adapter is used on Selkirk Metalbestos™ and other
Ø2.950" I.D. Pellet Vent Pipes.
Use conduit pipe or metal flex pipe and/or fittings to make
the air intake hook-up.
Also, the structural integrity of the mobile home floor,
walls and ceiling/roof must be maintained.
1. Clean and inspect the fireplace and its chimney for any
structural defect that may cause any future problems.
Secure gas piping that is installed with a cap and verify
there are no leaks. Seal ash dump or any other access to
the firebox area. Fix the damper in an open position or
remove it as required for vent pipe installation.
2. Verify the required hearth and side and clearances to
mantels (fig. 2 & 3).