Analysis Spot: Allows up to four spot measurements to take place on saved or
frozen images.
Analysis Line: Allows line profile measurement to take place on saved or frozen
images
Analysis Area: Allows up to four rectangular area measurements to take place on
saved or frozen images, displaying maximum, minimum and mean temperatures.
Analysis Isotherm: Allows for an isotherm to be placed on live, saved or frozen
images.
To exit the menu system at any time and return to the image press C Key.
Switching Between Infrared Image and Visual Image
You can toggle between the infrared image and visual image
When there is no menu on display screen, press the Key to switch between
thermal and visual images.
For replayed images, press the OK Key to switch between infrared image and visual
image.
Adjusting the Exposure and Gain of the Visual Image
There are two modes available - Auto Mode and Manual Mode.
Press
Key to switch between Auto Mode and Manual Mode. The current mode is
displayed in the left corner at the bottom of the display screen.
In Manual Mode, exposure control (EC) and gain control (GC) is available on the
screen.
Press the or Keys to adjust the value of the highlighted item and press
Key to shift between EC and GC.
In Auto mode, EC and GC will be defined automatically by the system.
Laser Locator
To turn on the laser locator option, press the M Key to display the main menu. Press
the , ,
or
Keys to highlight the “Setup Analysis” option. Select by
pressing the M or OK Keys.
Under the heading named “Laser”, you can toggle between “on” and “off” by pressing
the and Keys. The selection “on” is confirmed by pressing the M or OK Keys.
When there is no menu on the display screen, press the Key to turn the laser on