Configuring the SX-560
Silex
Page 23
Part Number 140-00192-100
3. Right-click on the SX-560 that you want to
configure from the displayed list, and then left-
click on Configuration. The default SX-560
name is SDSxxxxxx (where xxxxxx is the last
six digits of the MAC address from the label
that is affixed to the SX-560).
4. If you do not have a DHCP server, you will be
asked to manually enter an IP address (if you
are not sure what IP address to enter, ask
your network administrator). Click OK when
you are finished.
5. The Server Configuration window will appear.
Check the IP address setting to make sure it
is correct. If necessary, change the Subnet
Mask and Gateway. If you have a WINS
server, enter its address or click Use DHCP
to Locate WINS Server. If desired, you can
configure advanced TCP/IP settings by
clicking the Advanced TCP/IP button (refer to
Chapter 6 for information). This advanced
configuration can be done at a later time,
however.
NOTE: If you are using DHCP on your network, the SX-560
should have acquired valid IP settings at this point and no
further IP address configuration is necessary. However,
for some installations, a static IP address is preferred. If
your DHCP server does not allow the SX-560 to keep its
assigned IP address permanently, then you must
manually assign an IP address. In this case, use a static
IP address outside the range reserved for DHCP (see your
DHCP server documentation for details). To assign a
static IP address, select Set Permanent as the IP Address
Resolution, and assign a valid static IP address for your
network. Click on OK to save the new settings.