- Silex Technology Embedded Intelligent Module Developer's Reference Guide

Silex
Advanced Configuration
Part Number 140-00192-100
Parameter
Command
Description
Echo control
ATEn
If n=0, commands are not echoed.
If n=1, subsequent commands will be echoed.
The default, upon unit reset, is for no echo (ATE0).
Disconnect
ATHn
If n=0, any connection to a remote host is dropped.
Other value of n is ignored.
Return to data mode
ATOn
Exits command mode and places the serial port in
the data mode.
All subsequent data is sent to the network
application, if connected, until an enter command
mode sequence is received. Any value of n is
ignored, if present.
Quiet mode
ATQn
If n = 1, no result codes are returned.
If n = 0, result codes are returned to the local device.
0 is the reset default value.
Verbose mode
ATVn
If n = 0 and not in quiet mode, result codes are
returned in numerical form.
If n = 1, results are returned as text. 1 is the reset
default value.
Table 29 Extended AT Commands
Parameter
Command
Description
Console pass through
AT#C<string>
Passes the string to the server configuration console.
The string can be any valid console command. Refer
to your server documentation for console commands
available on your unit.
Since this command does not follow the normal AT
command format of <command><number>, it must
be the last command on the line unless the next
command is a '#' command. All characters up to the
end of line or a '# will be considered part of the
console command.
If console quiet mode is not is enabled, then the
response will be the standard console task response.
Example:
AT#Cset nw ssid silex#Csave
Console Quiet mode
AT#Qn
If n = 0, a response to a #C command is given.
If n = 1, the response is not provided. The default
after reset is 1.