- Silex Technology Embedded Intelligent Module Developer's Reference Guide

Silex
Console Commands
Part Number 140-00192-100
Command
Description
SH IP
Shows TCP/IP related parameters
Sample Output:
IP is enabled
IP address 192.0.0.192 Boot tries 3
Subnet mask 0.0.0.0 Boot method AUTO
IP Gateway 0.0.0.0 Max window 10240
(set manually)
LPD banner disabled Timeout 1 min
LPD retries are disabled Keepalive 5 min
Service Port TCP port
xxxxxx_S1_A S1 9100
xxxxxx_S1_B S1 3001
SET IP TRAP n
TRIG <trigger-
mask>
Specifies the trigger conditions that will cause a trap to be sent. <trigger-mask> is an
integer in hex format representing a 32-bit mask as defined below. If the
corresponding bit is 1, the trigger condition is enabled to cause the trap.
NOTE: Even if the trigger bit is set by this command, no trap will be entered if the
underlying trigger has not been configured.
Bit#
Hex Value
Trigger Condition
0
00000001
Serial Server: Match string 1
1
00000002
Serial Server: Match string 2
2
00000004
Serial Server: Match string 3
3
00000008
Serial Server: Match string 4
4
00000010
Serial Server: Match string 5
5
00000020
Serial Server: Match string 6
6
00000040
Serial Server: Match string 7
7
00000080
Serial Server: Match string 8
8
00000100
undefined
9
00000200
undefined
10
00000400
undefined
11
00000800
undefined
12
00001000
undefined
13
00002000
undefined
14
00004000
undefined
15
00008000
undefined
16
00010000
GPIO Trigger1: GPIO1 0 to 1
17
00020000
GPIO Trigger2: GPIO2 0 to 1
18
00040000
GPIO Trigger3: GPIO3 0 to 1