Specifications

1. GENERAL
2. AC INPUT SPECIFICATIONS
Parameter
Minimum
90Vac
180Vac
132Vac 15A
7.5A
264Vac
47Hz
Norminal
100-120Vac
200-240Vac
50-60Hz 63Hz
Maximum Max.Current
This is the specification of Model OP1000-Evolution; it is intended to describe the functions
and performance of the subject power supply. This PS/2 1000 watts switching power supply
with Active PFC (Power Factor Correction) capability, meets EN61000-3-2 and equips Full
Range Input features.
2.1 AC Input Voltage, Frequency and Current ( Rating: 100V-240Vac,
47-63Hz, 15-7.5A )
The power supply must operate within all specified limits over the input voltage range in
Table 1. Harmonics distortion of up to 10% THD must not cause the power supply to go
out of specified limits.
Table 1 – AC Input Voltage and Frequency
The power supply must meets inrush requirements of any rated AC voltage, during turn
on at any phase of voltage, during a single cycle AC dropout condition, during repetitive
On/Off cycling of AC, and over the specified temperature range. The peak inrush current
shall be less than the rating of its critical components (including input fuse, bulk rectifiers,
and surge limiting device).
2.2 AC Inrush Current