6.2 AC Input Leakage Current
Input leakage current from line to ground will be less than 3.5mA rms. Measurement
will be made at 240 VAC and 60Hz.
7. Reliability
7.1 Mean Time Between Failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis
method of MIL217F or Bell core RPP. The calculated MTBF of the power supply shall
be greater than 100,000 hours under the following conditions:
Full rated load
120V AC input
Ground Benign
25°C
Technical information in this specification is subject to change without notice.
8. Connections
8.1 AC Input Connector
The AC input connector shall be an IEC 320 C-14 power inlet. This inlet is rated for 15
A/250 VAC.
8.2 DC Wire Harness and Connector Requirements
M/B 24PIN connector
1
2
3
4
5
6
7
8
9
10
11
12
Pin Signal Color Size
13
14
15
16
17
18
19
20
21
22
23
24
16 AWG/ 22AWG
+3.3 VDC;+3.3VRS+
Orange / Brown