Specifications

02
Maximum inrush current from power-on (with power on at any point on the AC sine) and including,
but not limited to, three line cycles, shall be limited to a level below the surge rating of the input line
cord, AC switch if present, bridge rectifier, fuse, and EMI filter components. Repetitive ON / OFF
cycling of the AC input voltage should not damage the power supply or cause the input fuse to blow.
3. INPUT ELECTRICAL SPECIFICATIONS
Min.
90
150
47
Parameter
Frequency
(115VAC)
(230VAC)
Nom.
(1)
115
230
--
Max.
150
265
63
Unit
VAC rms
HZ
VAC rms
3.1 AC INPUT
3.2 INRUSH CURRENT
Nominal voltages for test purposes are considered to be within ±1.0V of nominal.
(Cold start - 25 deg. C)
115V
230V
No damage
No damage
EN 55022:1998+A1: 2000, Class B
EN 61000-3-2: 2000
EN 61000-3-3: 1995+A1: 2001
EN 60950-1
CISPR22: 1997+A1: 2000, Class B
AS/NZS CISPR 22: 2002, Class B
2.2 SAFETY
- NEMKO EN 60950-1
- TUV EN 60950-1
- CSA EN 60950-1
- IEC EN 60950-1
- UL EN 60950-1
- CE :