Strider Essential Series ST70F-ES / ST60F-ES Power for everything you need High efficiency with 80Plus certification 24hour continuous power output with 40 C operating temperature Class-leading single +12V rail Multiple protection circuitry Silent running 120mm fan with 18dBA PCI-E 8pin and PCI-E 6pin connector support ATX 12V 2.3 support Active PFC circuitry o November, 2010 NO.
Strider Essential Series SPECIFICATION 2.2 Input Frequency SilverStone Essential Plus ST70F-ES ST60F-ES 2.2.1 ST70F-ES ATX12V 2.3 Switching Power Supply With Active PFC PS/2 2.2.2 ST60F-ES Nominal Frequency Frequency Variation Range 50-60 Hz 47 Hz to 63 Hz Nominal Frequency Frequency Variation Range 50-60 Hz 47 Hz to 63 Hz * The power supply must operate at above frequency with 90-264 VACrms input voltage range. 1.GENERSAL 1.1.
Strider Essential Series STRIDER ST1000 ST1000-NV 3.1.2 ST60F-ES 2.5 Efficiency ST70F-ES, ST60F-ES provides an efficiency of >80% when measured at full load under 115V/60Hz and 230V/50Hz condition. 3. OUTPUT CHARACTERISTICS 3.1 Normal Operation Output 3.1.1 ST70F-ES Load MIN Range MAX Peak Regulation Ripple P-P Max 1. +5V 0.2A 25A -- ±5% 70mV 2. +12V 0.6A 42A -- ±5% 120mV 4. -12V 0.0A 0.3A -- ±5% 120mV 5. +5Vs 0.0A 2.5A -- ±10% 70mV 6. +3.3V 0.
Strider Essential Series 3.3 Regulation 3.7 PG-OK The cross regulation defined as follows, the output regulation should be within the specified range. PG-OK is a power good signal and should be asserted high by power supply to indicate that the +5 VDC and +3.3 VDC outputs are above the under-voltage thresholds of the power supply. When this signal is asserted high, there should be sufficient mains energy stored by the converter to guarantee continuous power operation within specification.
Strider Essential Series 3.8 3.3V Sense A default 3.3V sense line should be implemented pin 13 of the connector. 3.9 Capacitive Load The power supply should be able to power up and operate normally with the following capacitances simultaneously present on the DC outputs. Output +5V +12V +3.3V -12V +5VS Capacitive load (uF) 6,000 8,000 6,000 350 350 4.2.5 Over-Current Protection Current protection should be designed to limit the current to operate within safe operating conditions.
Strider Essential Series 6.3 Vibration and Shock 6.3.1 Sweep and resonance search for each of X,Y,Z, axis at the sweep. Frequency Duration Amplitude 5-55-10 Hz 30 minutes 0.35 mm Time Diagram 7. CONDUCTED EMI FCC, CE 8. PRODUCT SAFETY 8.1 Safety Requirement TUV, UL/c-UL,CB 8.2 Leakage Current The AC leakage current is less than 3.5mA when the power supply connect to 253Vac/50Hz . 8.
Strider Essential Series ATX 12V 4PIN (4+4PIN EPS 12V in split mode) 13. Power Factor The power supply with active power factor correction, and meet the EN61000-3-2 standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load. 14. MECHANICAL REQUIREMENTS 14.1 Physical Dimension 150 mm (W) × 86 mm (H) × 140mm (D) 14.2 Connectors M/B 24PIN connector Pin Pin Signal +3.3V 13 1 +3.3V Orange Blue -12VDC 14 2 +3.