7.10 EN55022 Class B Radio interference (CISPR 22).
7.11 FCC Part 15, Subpart J class B 115VAC operation.
8. MTBF
9. MECHANICAL REQUIREMENTS
8.1 MTBF (mean time between failures) calculation
The demonstrated MTBF shall be 100,000 hours of continuous operation at 25oC,
at 80% load, and nominal line. The MTBF of the power supply be calculated in
accordance with MIL-HDBK-217F. The DC FAN is not included.
9.1 Physical Dimension
150 mm (W) × 86 mm (H) × 150mm (D)
9.2 Connectors
M/B 24PIN connector
 
Orange
Blue
Black
Green
Black
Black
Black
White
Red
Red
Red
Black
Signal
+3.3V
-12VDC
COM
PS-ON
COM
COM
COM
N/C
+5VDC
+5VDC
+5VDC
COM
Pin
13
14
15
16
17
18
19
20
21
22
23
24
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Signal
+3.3V
+3.3V
COM
+5VDC
COM
+5VDC
COM
PWRGOOD
+5Vsb
+12V
+12V
+3.3V
 
Orange
Orange
Black
Red
Black
Red
Black
Grey
Purple
Yellow
Yellow
Orange