Integration Guide

REV070219
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 8 |
4.4 Conext Battery Monitor Settings
The Schneider Electric Conext
TM
Battery Monitor provides a more accurate state of charge (SOCS)
reading for the PHI battery bank. The Conext
TM
Battery Monitor indicates hours of PHI battery-based
runtime and determines PHI battery bank state of charge. The Conext Battery Monitor shares key PHI
battery bank parameters with Conext XW+ inverter/chargers, improving the overall system performance
of the battery bank.
Table 3.0 - Settings for SimpliPhi PHI 3.8 kWh 48V Battery w/Schneider Conext Battery Monitor
Conext Battery Monitor Settings
Setting
Value
Capacity
2
75Ah (per PHI 3.8)
Discharge Rate
20 Hrs
Nominal Temp
67F
Shunt Amps
500
Shunt mV
50
Self Disch
<1%/Month
Discharge Floor
20%
Float Voltage
53.32
Float Amps
2%
Auto Sync Time
240 Sec
Temp Unit
Celsius
Back Light Timer
30 Sec
Peukert Expo
1.05
Charge Eff Mode
Automatic
Temp Coeff
0.5Ah/degC
Default Temp
76 Deg F
Sync Sensitivity
5
Time Rem Filter
Faster
CAUTION: When PHI battery quantities change, the capacity & charge/discharge current settings
must be reassessed. Failure to do so will void the Warranty.