Instruction manual

Installation and service Chapter 12-13
SimNet power and termination
The following simple rules should be observed when installing SimNet:
• SimNet must be powered with 12 VDC and connected to the battery via
circuit breaker and 5 amp fuse.
• Do not connect the SimNet power cable to the same terminals as the
Autopilot Computer, Radar, thruster or other high current products.
• SimNet should normally be terminated in each end, starting with the power
cable with termination in one end and termination plug or wind transducer
(with termination) in the other end.
12.5.5 Universal connection cable
Transducers are recommended to be 60 to 80 ohms and minimum 1kW. The
universal connection cable should be applied for connecting one or two trans-
ducers to either ECHO1 or ECHO2 port.
Connection cable (153-3004-002)
Cable type AMW STYLE 2464
Pin ECHO1 ECHO2
50&200kHz 38&200kHz
1 Red Speed log Depth 1+
2
Black (brown)
VCC speed Depth 1-
3 Blue Depth 1+ Depth 2+
4 Shield Shield Shield
5
White (orange) Depth 1- Depth 2-
6 Green GND* GND (Temp.)
7 Yellow Temp. Temp.
*) Temp./Speed log