Instruction manual

Table Of Contents
Installation
22083083K 67
Note ! Gyros with stepper or geared synchro output can not be used when GI51 is
connected to AP35 via Robnet. Then GI51 must be installed as a stand alone
unit, using NMEA heading output to J3XX port #2.
Figure 4-31A GI51 Alternative connection
Note ! For heading offset and alignment, see GI51 Manual.
4.31 CD100A Course Detector
On some installations the owner may prefer to use the boats own compass.
The compass must be fully gimballed and have a flat surface underneath to
fit the CD100A. Make hole for a 6 mm screw in the bottom of the compass
and mount the CD100A as shown on the drawing. Secure the 6 mm screw
through the centre hole of the CD100A. Make sure the cable does not
prevent the compass from moving freely in the gimbals.
Note!
Lock nut on mounting screw (pos.
1) for transportation only. To be
removed before mounting.
Figure 4-32 CD100A mounting
1 Screw M6x25mm, non
magnetic
2 Washer, non magnetic
3 Course detector
4 Cable clamp, nylon
5 Washer, non magnetic
6 Screw M3x10mm, non
magnetic
3
2
1
4
5
6