Instruction manual
Table Of Contents
- SIMRAD AP35 AUTOPILOT
- DOCUMENT HISTORY
- 1 GENERAL INFORMATION
- 2 OPERATION OF THE AUTOPILOT
- 2.1 Overview
- 2.2 ON/OFF - Standby mode
- Follow-Up steering
- 2.4 Non-Follow-Up steering
- 2.5 NFU Steering lever
- 2.6 NFU Push button remote control
- 2.7 R3000X Remote Control
- 2.8 S35 NFU Steering Lever
- 2.9 Automatic Steering
- 2.10 Automatic Speed selection
- 2.11 Manual speed selection
- 2.12 Navigating with the AP35
- 2.13 WORK-mode
- 2.14 TURN-mode
- 2.15 Dodging
- 2.16 Multiple station system
- 2.17 Lock function
- 2.18 User Set-up Menu
- 3 TECHNICAL SPECIFICATIONS
- 3.1 AP35 Autopilot System
- 3.2 AP35 Control Unit
- 3.3 Junction units
- 3.4 RFC35 Fluxgate compass
- 3.5 RC25 Rate Compass
- 3.6 CDI35 Course Detector Interface
- 3.7 RI35 Mk2 Rudder Angle Indicator
- 3.8 RF300 Rudder Feedback Unit
- 3.9 RF45X Rudder Feedback Unit
- 3.10 R3000X Remote
- 3.11 GI51 Gyro Interface
- 3.12 NI300X NMEA Interface
- 3.13 S35 NFU Steering Lever
- 3.14 FU50 Steering Lever
- 3.15 IP protection
- 4 INSTALLATION
- 4.1 General
- 4.2 Installation checklist
- 4.3 Unpacking and handling
- 4.4 Determine system configuration
- 4.5 AP35 System Layout
- 4.6 RF300 Rudder feedback
- 4.7 RF45X Rudder Feedback Unit
- 4.8 Junction unit
- 4.9 Drive unit
- 4.10 Control unit
- 4.11 RFC35 Fluxgate Compass
- 4.12 RC25 Rate Compass
- 4.13 R3000X Remote Control
- 4.14 FU50 Steering Lever
- 4.15 S35 NFU Steering Lever
- 4.16 F1/2 Remote Control
- 4.17 RI35 Mk2 Rudder Angle Indicator
- 4.18 Interfacing
- 4.19 Single NMEA input/output
- 4.20 Double NMEA input/output
- 4.21 Additional NMEA output on Port 2
- 4.22 Input from “NMEA Compass”
- 4.23 Radar Clock/Data
- 4.24 IS15 Instrument
- 4.25 Analog Repeater
- 4.26 Digital Repeater
- 4.27 External Alarm
- 4.28 NI300X NMEA Interface Unit
- 4.29 CI300X Compass Interface
- 4.30 GI51 Gyro Interface
- 4.31 CD100A Course Detector
- 4.32 CDI35 Interface
- 4.33 Software Setup Procedure
- 4.34 Sea Trial
- 4.35 Final sea trial
- 4.36 Providing user training
- 5 MAINTENANCE
- 6 TROUBLE SHOOTING
- 7 SPARE PARTS LIST
Installation
22083083K 79
Interface setup - input signal
Setup item
(abbrev.
name)
Equipment
connected
Connected to terminal
(use one available from list)
Assign hardware
port to setup item
(* = default setting)
GPS1 Not connected –
J3XX, Main PCB NMEA I/P
RX1+,RX1–
J300X-1 *
(on J3000X)
J300X, Power PCB NMEA I/P
RX2+,RX2–
J300X-2 *
(on J300X and J300X-
40)
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
GPS2 Not connected – *
J300X, Main PCB NMEA I/P
RX1+,RX1–
J300X-1
J300X, Power PCB NMEA I/P
RX2+,RX2–
J300X-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
LC1 Not connected – *
J3XX, Main PCB NMEA I/P
RX1+,RX1–
J300X-1
J300X, Power PCB NMEA I/P
RX2+,RX2–
J300X-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
LC2 Not connected – *
J300X, Main PCB NMEA I/P
RX1+,RX1–
J300X-1
J300X, Power PCB NMEA I/P
RX2+,RX2–
J300X-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
NAV1 Not connected – *
J3XX, Main PCB NMEA I/P
RX1+,RX1–
J300X-1
J300X, Power PCB NMEA I/P
RX2+,RX2–
J300X-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
J3XX = All junction unit models