Operation Manual

14 |
Introduction | AP70/AP80 Installation Manual
Computer boards
Indicator diodes and switches
Indicator diodes and switches are available on the boards as shown in the tables below.
LED Description AC70 AD80 SD80 SI80
Polarity
check
Red: wrong polarity
Green: correct polarity
x x
CPU
1Hz alternating green: CPU is running correctly
Rapid flashing: Application program is missing
x x x x
HS Green: Handshake output is on x x
RX Living green: Serial data is received x x
SOL Green: Solenoid command is given x
Switch Description AC70 AD80 SD80 SI80
U_CTRL
Selection of internal ±10 V or external
reference voltage for analog voltage control
output.
¼ Note: For 4-20 mA current control,
switches must be set to internal ref.
voltage
x
U_IN RANGE
Range setting of analog voltage input signal
for rudder feedback, follow up wheel or
remote DP control
x x
SIMNET
TERMINATION
ON (to the left) or off setting of 120 ohm
CAN bus termination.
¼ Note: Termination must be set to ON
when the board is at one end of the
CAN bus backbone, otherwise it must
be set to OFF.
x
AC70 board
Drive computer board for rudder or propeller (i.e. Voith Schneider) for reversible motor or
galvanic non-isolated solenoids.
Includes:
SUPPLY - power supply 12/24 V in
DRIVE - output for Motor or solenoid command
DRIVE ENGAGE - output for clutch/bypass valve or automode signal for oil flow valve etc
ALARM - Output for external alarm buzzer
NMEA 0183 - in/out for IEC 61162-1, -2 and NMEA 0183
RUDDER - Input for frequency rudder feedback
REMOTE - Input for NFU steering lever
MODE - Input for external mode selector
SIMNET - connection to CAN network
DRIVE
30 A FUSE
POLARITY LEDS
DRIVE
ENGAGE
SUPPLY
NMEA0183
ALARM MODE
SCREEN
TERMINATION
REMOTE
SIMNET
RUDDER
POLARITY
CHECK
CPU
HS1
RX1
SOL2
SOL1
U_CTRL
EXT
READY
ON
INT
U_IN RANGE
+20V
+10V
+5V
SIMNET
TERMINATION
AC70
SD80 SI80
AC85
AC85 AC85
AC80S
AC80A
AC80S
AD80
AC85
AC80A