Instruction manual

Chargingandmaintenance
CHARGINGANDMAINTENANCE
ThischapterexplainshowyoushallrechargethebatteryinthePI
SeineSoundersensor,andhowyoushallbestmaintainthesensor.
PISeineSoundermaintenance
Onceinstalledandputtouse,thesensorwillautomaticallybe
switchedononcethewaterswitchisactivated.Afteraninitial
start-up,thesensorstartstransmissionofthemeasureddatait
collects.
Whenthesensorisnotinuse,checkthatthesensorlampisnot
ashing,asthisindicatesthatthesensorisactiveanddischarging
itsbatteries.Inthiscase,washthesensorinfreshwater.
Allsensorsareequippedwithawaterswitch,andtwodifferent
typesareused.Ifyoursensorisequippedwithasacricialbrass
screw,observethefollowingprocedureforreplacement.
1Turnthesensorupsidedown,andlocatethebrassscrew.
2Inspectthescrewforwearandtear.
3Ifreplacementisrequired,locateanewscrew.
Beforeanewscrewisinserted,AquaShield(orasimilar
underwaterlubricant)mustbeapplied.Duetothesizeof
thetube,werecommendthatthegreaseisappliedfrom
asyringe.
4ApplyAquaShieldtothescrewthreads.
5Insertthescrew,mountrmly,butnottoohard.Use
maximumtorque1.5NM
ApackwithtenscrewsandatubeofAquaShieldcanbe
orderedfromSimradasasparepartskit.
AquaShieldismanufacturedbyD.A.Stuart,Warrenville,
Illinois,USA.
Visitw
w w . d - a - s t u a r t . c o m .
Noothermaintenanceofthesensorisrequired.
Note
Youmustn e v e r attempttoopenthesensor.Therearenouser
serviceablepartsinside,andyoumayeasilycausealeak.
313700/D
27