General guidelines
Operational time and service life of the sensors NiCd battery
depends on proper use and regular charging. Observe the
following precautions, as these will have an influence on the
battery performance:
Observe the char ging temperatures.
Charge sensors regular ly. Avoid draining the sensor battery
completely before charging.
Charge the sensor battery before storage, and at three-month
intervals under long-term storage.
Operational life may be initially reduced after long-term
storage or charging for a long time.
Sensors are not damaged by being left attached to a charger
for several days. However, do not store the sensor for
extended periods under charge.
We recommend that a wooden box is made to keep the sensor
in a secure place during charging and storage. Make openings
in the bottom to drain for sea water.
Battery depleted frequently
If the charger lamp is illuminated, but the sensor lamp does not
flash every four seconds, the battery is not being charged
properly. Most likely, this is because the sensor was not
switched off when the charger was connected.
To correct, charge the sensor for ten minutes, then disconnect
the alligator clips. Use a small wire, and make contact between
the water switch sensor and one of the fastening lugs. This will
cause the sensor to flash its start-up code. If not, wash the sensor
in fresh water to disengage the water switch.
Typical sensor (PI Depth)
(A) = Negative charging / fastening lug
(B) = Positive charging / fastening lug
(C) = Communication link
(D)=Locationofsensorlamp
(E) = Water switch sensor
(F) = Water pressure sensor