Operation Manual

References
197
850-165186 / Rev.B
Marker line setup
These settings are used to set up the PI54 parameters related to
the marker lines on the graphic display. When enabled, these
marker lines will be superimposed on the graphic display.
To access the parameters, press the ADJ button when you have
a graphic display in the active window. Then, press the GAIN+
button two times until the settings appear. You can also press the
MENU button to access the Echo quick menu, select Graphic
setup (8), and then press the GAIN+ button until the setup
dialogue appears.
The Marker line setup controls how the markers from the
applicable sensors are displayed on the Graphic display. The
setup function will read the current sensor configuration, and list
the relevant sensors on the menu.
In the example provided, the PI54 is set up with two Depth
sensors, one Height sensor, as well as input from a surface
temperature feeler. These will all provide information to the
graphic display. Those sensors that will not provide presentable
information will not be listed.
Note: The Catch and Bottom Contact sensors will not be able to
provide information for such markers, as they only trigger
on/off.
Auto: This option allows you to enable and use the delay
automatically calculated by the Trawl calculator. Select On to
enable the function. The current delay is then shown with grey
characters, and the values can not be edited. If you select Off
you must enter the Delay values manually. Note that the Trawl
calculator must be enabled to provide the delay information. If
such information is unavailable, the On/Off choice is shown
with grey characters.