Operation Manual

Simrad PI54
212
850-165186 / Rev.B
Sensor alarms
This dialogue allows you to defi ne alarms related t o the
information provided by the sensors you have in curr ent use on
your PI54 system. The appearance of the dialogue will thus
automatically change to suit your individual configuration.
Sensor alarm
MENU Exit
GAIN- GAIN+
(CD11103W-A)
0010m OFF
0120m OFF
0060m OFF
-0.5°C OFF 10.0°C OFF
0100m ON
LIFT-OFF ON
ON
0350m OFF
0010m ON
Min alarm Max alarm
Height 2:
Depth 3:
Spread 4:
Temp 5:
Bottom sensor alarm:
Catch sensor alarm:
Each sensor has an individual alarm setting. To enable an alarm,
you must define minimum and maximum limits for the sensor,
and set it to ON. If the alarm is triggered, an audible signal will
be provided, and a message will tell you which sensor that
caused the alarm. Once an alarm has been triggered, it is
automatically disabled for 20 seconds. Af ter this time it may be
triggered again unless the alarm situation has been rectified, or
you have disabled the alarm.
The Bottom Contact and Catch sensors can only provide
alarms when they are activated.
Related topics
How to define alarm limits, page 96