Sensor setup
These parameters are used to establish communication between
the PI54 and the sensors.
To access the parameters, press the MENU button to open the
main menu, Then select Sensor setup on the Setup menu.
Note: In order to set up these parameters correctly, you need to know
what kind of sensors you have, how often the provide
information updates, and on which channels they communicate.
A form has been provided in the front of this book to write down
this information.
For each of the sensors, enable it, and select sensor type,
communication rate and communication channel.
Sensor: Choose Single to enable the sensor, or None to disable
it.
Measur e : Choose the sensor type.
Update: Select Normal, Fast or Slow. This is the time elapsed
between each information update from the sensor. The setting
you choose here must
match with the setting defined in the
applicable sensor.
Channel: Select any channel between 0 and 30, or No (none).
The setting you choose here must
match with the setting defined
in the applicable sensor.
Demo mode: Set to Off to enable normal operation using
sensors and echo sounder transducer.