Operation Manual

Display modes
47
850-165186 / Rev.B
(D) = Gain indicators for the current sensors
(E) = Lower status field
(A) Numeric information
The numeric displays at the top of the Status display provide
the current information from the active sensors. Due to the lack
of space, the information from the sensors have been
abbreviated slightly. For a more detailed presentation, you must
select the the Numeric display presentation.
(B) Upper status field
The upper status field provides an overview of key parameters.
Receiver setup: All the par ameters on the left side are those
defined by the Receiver setup dialogue. To change these, press
the MENU button to access the Setup menu (4), and select
Receiver setup (6).
SW: This sentence provides the current software version in your
PI54 system. Main is the operational software providing the
user interface, ยตC is the PI54 microcontroller, while DSP is the
software controlling t he digital signal processor, that is the
reception and interpretation of sensor information.
Max sh. speed: This is the maximum shooting speed as defined
in the Receiver setup dialogue.
Demo: This entry shows you if the sensor demonstration mode
has been activated. To switch the Demo mode on or off, access
the Sensor setup.
Last received ch: This entry shows you which of the sensors
that last provided information to the PI54.
Error: This is simply an error code. This information is
provided for test purposes only. Unless a software error occurrs,
the code will be 0 (zero).
Hydrophone: A yellow indicator is provided when the
hydrophone is connected and fully operational. If the indicator
is red, a short circuit has occurred. If the indicator is black, the
PI54 has lost electrical contact with the hydrophone.
NMEA1/2: Any information accepted by the NMEA interface
will pr ovide a green indicator. If the indicator is black, the PI54
is currently not receiving input traffic, however, information
may still be exported continuosly.