Operation Manual

Operational procedures
69
850-165186 / Rev.B
Sensor setup
Observe the procedure below to set up a Twin Spread
configuration with its default settings.
In this procedure, sensors 1 and 2 are used, and no other sensors
are shown. Due to the fact that the Twin Spread sensor occupy
two communication channels, the setup program requires that it
is configured as if it was two separate sensors, but not
necessarily sensors 1 and 2. The remaining four channels can be
used for other sensors.
We strongly suggest that you use the form s in the front of this
manual to write down the sensor you have with information
about their update rates and communication channels.
1 Press the MENU button to open the main menu.
2 Open the Setup menu (4), and select Sensor setup (5).
3 Press the ENT key to bypass the warning page.
4 To configure the Twin Spread sensor, enter the following
parameters:
a Set Sensor 1 type to SINGLE to activate the sensor.
b Set Update 1 rate to FAST.
c Set Measure 1 to SPREAD.
d Set Channel to 02.
e Set Sensor 2 type to SINGLE to activate the sensor.
f Set Update 2 rate to FAST.
g Set Measure 2 to SPREAD.
h Set Channel to 07.
5 For operational use, make sure that Demo mode is set to
OFF.
6 When you have defined the sensors, press the ENT
buttom to save the changes and exit.