Operation Manual

Simrad PI54
70
850-165186 / Rev.B
According to the sensor locations pr eviously described, Spread
1 will now measure the distance from the port trawl door to the
centre clump, while Spread 2 will measure the distance from the
port trawl door to the starboard trawl door.
Readout adjustments
It is necessary to set certain parameters in order to have the PI54
to calculate the distance from the centre clump to the starboard
trawl door.
Headrope sensor:
Footrope sensor:
Trawl opening mode:
Clump sensor:
Door sensor:
Manual trawl marker:
Trawl info
MENU Exit
GAIN- GAIN+
(CD11105C)
Trawl data in additional info:
Type of trawl data:
ON
SPREAD
SPREAD 1
SPREAD 2
1 Press the MENU button to open the main menu.
2 Press the WIN button to select a full screen presentation.
3 Open the Fishery menu, and select a Graphic d isplay.
4 Press the ADJ button to open the Graphic setup.
5 Press the PAGE+ button three -3- times to access the
Trawl info dialoge.
6 Locate the Clump sensor setting, select SPREAD 1.
- As previously defined and described, sensor Spread 1
measures the distance between the port trawl door and
the centre clump.
7 Locate the Door sensor setting, select SPREAD 2.
- As previously defined and described, sensor Spread 2
measures the distance between the port and the
starboard trawl doors. This setting allows the PI54 to
calculate the distance between the clump and t he
starboard trawl door.
8 Locate Trawl data in addit ional info, select ON.
9 Locate Type of trawl data, select SPREAD.
10 Press the ENT button to save the settings and exit.
Readouts
Following the configuration and r eadout adjustments explained,
the following readouts are now available in the Graphic
display.