Operation Manual

Operational procedures
87
850-165186 / Rev.B
Trawl opening mode: T his parameter decides how the trawl
opening shall be recreated on the graphic presentation. If you
have sufficient sensors on the trawl you must select Auto,
and the the PI54 will automatically calculate the trawl
opening and draw it accordingly. If you only have one sensor
on the trawl opening (Depth or Height sensor on the
headrope), the Manual setting will add an artificial line on
the presentation. The distance from the headrope to the
footrope must then be defined manually using the Manual
trawl marker parameter.
Access to the parameters
1 Make sure that a graphic presentation is active.
2 Press the ADJ button to open the Graphic setup
dialogue.
3 Press the GAIN+ button to access the Trawl info setup
page.
Set up the parameters
1 Locate the setting Headrope sensor, and choose the
sensor that you have placed on the headrope.
- If you have no Depth or Height sensors on the
headrope, leave the setting to None.
2 Locate the setting Footrope sensor, and chose the sensor
that you have placed on the footrope.
- If you have no Depth or Height sensors on the
footrope, leave the setting to None.
3 Observe that the setting for Trawl opening mode is
automatically set to Auto or Manual.
- If you have sensors placed on both the footrope and the
headrope, the PI54 will be able to calculate the trawl
opening automatically, and the mode is set to Auto.
- If you have only one sensor, you will need to enter a
manual trawl marker.
4 If you have only one sensor, enter a value for Manual
trawl marker.
- This value must represent the actual height of your
trawl opening, based on your knowledge about your
gear. The information will be used by the PI54 to draw
a second trawl marker line.
Related topics
Graphic setup, page 184
Marker line setup, page 197
Trawl info setup, page 223