Installation manual

Simrad SP70
60
850-164186 / Rev.D
Installation of options
The following options can be installed on the SP70 sonar:
90 tilt
Triple- or multiple-frequency
Scientific output
Note that all options are pre-programmed into the standard
sonar version, and that Simrad offer a 1 month free test period
for certain options. When ordering a permanent option
installation, a code word will be released from Simrad.
For a free test, or permanent option installation, use the
following procedure:
1 Select the Setup menu.
2 Press the Test button to activate the System test menu.
3 Press the Installation Menu button.
4 Observe that the installation menu bar is shown on the top
of the screen.
5 Press Options on the menu bar.
6 Select Install Options to activate the Install options
parameter dialogue.