INSTRUCTION MANUAL S D 1500T MARCH 2020
WHAT IS SITE DRAINER SD PUMPS? Site DrainerTM SD is an all 304 stainless steel electric, submersible dewatering pump system to use patented technology to remove water without clogging.
HOW IT WORKS Canister surrounding the pump diffuses water suction pressure over a large area Optional burlap sack accessory eliminates erosion concerns Fine mesh openings allow particles <6.35mm (.
SPECIFICATIONS Model SD 1500T Type Submersible Pump Impeller Polyurethane coated metal Discharge Size 3” Maximum Pumping Capacity 7200 gallons/hr 5’, 7200 gal/hr 10’, 7044 gal/hr 15’, 6718 gal/hr 20’, 6018 gal/hr 25’, 5280 gal/hr 30’, 5046 gal/hr 35’, 4800 gal/hr 40’, 4224 gal/hr 45’, 3852 gal/hr 50’, 3426 gal/hr 55’, 2652 gal/hr 60’, 1680 gal/hr N O N - C L O G G I N G 65’, S O L U T I 768 ON gal/hr 4 Discharge Height Above Pumping Level THE TM
SPECIFICATIONS Model SD 1500T Power 2 HP (1.5 kW) Voltage 220 v Power cable length 33’ one piece molded rubber Running Amps 20 amps Thermal Overload Protection Yes Dimensions 16.5”H, 10.0” D Dry Net Weight 63.25 lbs. Temperature 34 - 104 F Intermittent usage to 140 F (max.
THINGS TO KNOW 3” female discharge port – at top of pump, accepts 3” NPT male hose For greater versatility, can come with quick connect coupling Portable – 63.25 lbs, and has carrying handle Maneuverable into tight spaces, easily transported 304 stainless steel screen, 20 gauge thickness Debris larger than .
THINGS TO KNOW Pump and motor section form a pressure-tight encapsulated unit Motor housing constructed from stainless steel material Impeller made of cast iron Connection chamber with cover and watertight cable inlet and strain relief Motor is dynamically balanced with temperature monitor in the stator, which switches off the pump in the case of overheating and switches on automatically after cooling down Shaft is made of stainless steel Water being pumped flows around the motor housing
SAFETY INFORMATION Pump water only Never use worn or damaged cables. Inspect for cuts in the insulation. Never attempt to use the power cord as a lifting or lowering device for the pump Always lift the pump by it’s carrying handle or attached rope to carrying handle Always make sure electrical circuits are properly grounded A fully submerged pump in liquid will not freeze, unless the liquid freezes Do not allow a partially submerged pump to freeze.
WARNING Do not operate near potentially explosive environment Do not use in presence of flammable liquids or gases Make sure product is properly grounded and provided with leakage breaker to prevent users from serious electric shock Always turn off the power before inspection, maintenance, and adjustment Never attempt to change the settings of all protective devices without consulting with licensed electrician The product is designed for moving water.
WARNING Protect the electric plug or end of power cable from invasive moisture at all times Never touch the piping or electrical connections while the pump is running Never touch the water while the pump is under operation Never pump the pump into operation if it has been partially disassembled Never run the pump without water, do not operate the pump out of water or insufficient water Do not use the pump if the power cable is damaged T H E N O N - C L O G G I N G S O L U T I O N TM 10
PRODUCT WARRANTY Site Drainer’s sole obligation under this warranty shall be limited to the repair or replacement of any parts that the Seller determines, in its discretion, to be defective.
PUMP INSTALLATION Before installation, check you local electrical and plumbing regulations. These regulations are for your safety Use the pump dimensional drawing to ensure proper installation Make sure the cables are not kinked or nipped Ensure that hoses and valves are suitable for the pressure of the pump.
MAINTENANCE AND INSPECTION Regular checkups and preventive maintenance will ensure a more reliable and safe operation. An initial inspection of the pump within 3 to 4 months after installation is recommended.
EU REGULATORY NOTICE AND UL LISTING The product complies with the following EU directives: 2006/42/EC Machinery Directive 2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive UL 778 listing by May 1, 2020 T H E N O N - C L O G G I N G S O L U T I O N TM 14
TROUBLESHOOTING Problems Possible Causes Solutions Pump fails to start No electricity > Check power source Open circuit or poor connection > Check if there is an open circuit Impeller is clogged > Inspect the impeller Pump starts but stops immediately causing the motor protector to activate Impeller is clogged > Motor abnormal > The pump is picking up too much sediment > Inspect the impeller Repair the motor or replace Place the pump on a concrete surface to prevent sediment pickup The pump's head a
OPTIONAL ACCESSORIES Flexible Plastic Discharge Hoses 1-1/2” Double Male Threaded Aluminum Fittings Cocoa Fiber Baskets 1-1/2” to 2” Threaded Plastic Fittings Commercial Grade Discharge Hoses 1-1/2” PVC Fittings 1-1/2” Quick Disconnect Fittings T H E N O N - C L O G G I N G S O L U T I O N TM 16