Instructions

Pb Lead-Acid Battery Program
Pb Discharge Mode:
After selecting the correct battery type, use the INC or DEC buttons to change it to the
“DISCHARGE“ mode.
Press the START button and the amp rate value will begin flashing. Use the INC or DEC
buttons to adjust the value to the desired discharge rate. Follow the instructions provided
with your battery when setting the amp rate.
Press the START button again and the nominal battery pack
voltage will begin flashing. Use the INC or DEC buttons to set
the voltage and the number of cells.
Press and hold the START button and discharging will begin.
Once discharging has commenced, the charger will display the
following real-time information: battery type, cell count,discharging
current, battery voltage, elapsed time and discharged capacity.
When discharging is complete, the screen will read “FINISHED”
and the charger will emit a ringing sound.
Additional Pb Process Information:
During the Pb battery charging/discharging process the D260 can display a variety of
information. Using the INC or DEC buttons you can also view the following information:
PB DISCHARGE
1.5A 12.0V(6P)
P-6 1.0A 13.56V
DCH 005:10 00964
CAPACITY CUT-OFF
ON 5000MAH
SAFETY TIMER
ON 200MIN
INT. TEMP 37 C
Capacity cut-
off setting
IN POWER VOLTAGE
12.56V
Input voltage
Safety timer
setting
Internal temperature
Once charging has commenced, the charger will display the
following real-time information: battery type, charging current,
battery voltage, working mode, elapsed time and charged
capacity.
When charging is complete, the screen will read “FINISHEDand
the charger will emit a ringing sound.
P-6 1.5A 13.56V
CHG 002:22 00106
23 ·
D260