Specification Sheet
►► Code NumberCode Number
20011201
►► SpecificationsSpecifications
Quiet, exposed, diaphragm type, chrome plated closet HET
Flushometer and HET vitreous china floor mount fixture with the
following features:
►► Flush CycleFlush Cycle
1.1 gpf/4.2 Lpf
►► Flushometer SpecificationFlushometer Specification
● ● Flex Tube Dual Filtered Bypass Diaphragm designed for improved
life and reduced maintenance
● ● Latching Solenoid Operator
● ● Courtesy Flush® Override Button
● ● User Friendly Three (3) Second Flush Delay
● ● “Walk By” Delay of Eight (8) Seconds Prevents Unintentional
Flushes
● ● Sensor with automatic range adjustment
● ● Initial Set-up Range Indicator Light (first 10 minutes)
● ● Chrome plated Infrared Sensor Housing
● ● Engineered Metal Cover with replaceable Lens Window
● ● High Back Pressure Vacuum Breaker Flush Connection with One-
Piece Bottom Hex Coupling Nut, Spud Coupling and Flange for 1-
1/2" Top Spud
● ● Fixed Metering Bypass and no external volume adjustment to
ensure water conservation
● ● Free spinning, Vandal Resistant Stop Cap
● ● 1” I.P.S screwdriver Bak-Chek® angle stop
● ● Flush accuracy controlled by CID® technology
● ● Infrared Sensor with Multiple-focused,Lobular Sensing fields for
high and low target detection
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi-Red Brass.
Valve shall be in compliance to the applicable sections of ASSE
1037/ ASME A112.19.2/CSA B45.1
● ● PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
● ● Sweat Solder Adapter w/Cover Tube and Cast Wall Flange with
Set Screw
● ● Diaphragm, Stop Seat and Vacuum Breaker to be molded from
PERMEX® rubber compound for Chloramine resistance
►► Fixture SpecificationFixture Specification
● ● Recommended seats:
● ● Bemis - 1955CT/1955SSCT & 2155CT/2155SSCT
● ● Church - 295CT/295SSCT & 2155CT/2155SSCT
● ● Mounting hardware, carrier and toilet seat not included
● ● White Vitreous china
►► FEATURESFEATURES
AutomaticAutomatic
The Flushometer operates by means of an infrared sensor that
adapts to its surroundings. Once the user enters the sensor’s
effective range and then steps away, the Flushometer Solenoid
initiates the flushing cycle to flush the fixture.
Functional & HygienicFunctional & Hygienic
User makes no physical contact with the Flushometer surface.
EconomicalEconomical
Automatic operation provides water usage savings over other
flushing devices. Reduces maintenance and operation costs.
►► NoteNote
1.1 gpf flushometer only recommended in new contruction
installations or those where sufficient drain line carry can be assured.
Alternatives include 1.28 gpf or 1.6 gpf flushometers
►► Plumbing System Plumbing System RequirementsRequirements
Maximum Static Pressure: 80 PSI
Minimum Flow Rate: 25 GPM
Minimum Flowing Pressure: 25 PSI
►► Compliance & CertificationsCompliance & Certifications
This space for Architect/Engineer Approval
Floor Mount Water Closet Combo
Package
WETS 2001.1201-1.1 SOLIS®
2018-06-02 Page 1 of 2
SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. 60131 60131
Ph: 1-800-9-VALVE-9 or 1-847-671-4300 ● Fax: 1-800-447-8329 or 1-847-671-4380 ● http://www.sloan.com