Position Designation Description
A Configuration steps Overview of the Installation Assistant steps. The number of
steps depends on the type of device and the additionally
installed modules. The current step is highlighted in blue.
B User information Information about the current configuration step and the
setting options of the configuration step.
C Configuration field You can make settings in this field.
Procedure:
1. Select the configuration option Configuration with Installation Assistant.
The Installation Assistant will open.
2. Follow the Installation Assistant steps and make the settings appropriate for your system.
3. For every setting made in a step, select [Save and next].
In the last step, all made settings are listed in a summary.
4. To save the settings to a file, select [Export a summary] and save the file on your computer,
tablet PC or smartphone.
5. To correct settings you made, select [Back], navigate to the desired step, correct settings and
select [Save and continue].
6. Once all settings are correct, select [Next] in the summary.
7.
Accepting the settings
Saving the made settings is indicated by an hourglass symbol on the user interface. If
the DC voltage is sufficient, the data is transferred directly to the inverter and accepted.
If the DC voltage is too low (e.g. in the evening), the settings are saved, but they
cannot be directly transferred to or accepted by the inverter. As long as the inverter has
not yet received and accepted the settings, the hourglass symbol will continue to be
displayed on the user interface. The settings will be accepted when there is sufficient DC
voltage applied and the inverter restarts. As soon as the hourglass symbol appears on
the user interface, the settings have been saved. The settings will not be lost. You can
log off of the user interface and leave the system.
The start page of the user interface opens.
Manual configuration
You can configure the inverter manually by setting the desired parameters.
Procedure:
1. Select the configuration option Manual Configuration.
The Device Parameters menu on the user interface will open and all available
parameter groups of the inverter will be displayed.
2. Select [Edit parameters].
3. Select the desired parameter group.
All available parameters of the parameter group will be displayed.
7 Commissioning
SMA Solar Technology America LLC
Installation manual 55SB5.0-6.0-1SP-US-40-IA-xx-10