Installation Manual

10 Technical Data
DC Input
SB 5.0-1SP-US-40 SB 6.0-1SP-US-40
Maximum usable DC power at 208V 5300 W 5500 W
Maximum usable DC power at 240V 5300 W 6300 W
Maximum input voltage 600V 600V
MPP voltage range 100V to 550V 100V to 550V
Rated input voltage 220V to 480V 220V to 480V
Minimum usable input voltage 90V 90V
Initial input voltage 125V 125V
Maximum input current per input 10A 10A
Maximum short-circuit current per input 18A 18A
Number of independent MPP inputs 3 3
AC Output
SB 5.0-1SP-US-40 SB 6.0-1SP-US-40
Rated power at 208V 5000 W 5200 W
Rated power at 240V 5000 W 6000 W
Maximum apparent AC power at 208V 5000VA 5200VA
Maximum apparent AC power at 240V 5000VA 6000VA
Rated grid voltage 208 V / 240 V 208 V / 240 V
AC voltage range at 208V 183V to 229V 183V to 229V
AC voltage range at 240V 211V to 264V 211V to 264V
Nominal AC current at 208V 24 A 25 A
Nominal AC current at 240V 21 A 25A
Maximum output current 24A 25A
Total harmonic factor of output current <4% <4%
Line synchronization characteristics/inrush cur-
rent
Method 2/2.4A Method 2/2.4A
Rated power frequency 60 Hz 60 Hz
Operating range at AC power frequency 60Hz 59.3Hz to 60.5Hz 59.3Hz to 60.5Hz
Output power at +60°C (+140°F) >3300W >3300W
Power factor at rated power 1 1
10 Technical Data
SMA Solar Technology America LLC
Installation manual 61SB5.0-6.0-1SP-US-40-IA-xx-10