Installation Manual
SB 5.0-1SP-US-40 SB 6.0-1SP-US-40
Range of the displacement power factor (ad-
justable)
0.8
overexcited
to 0.8
underexcited
0.8
overexcited
to 0.8
underexcited
Feed-in phases 1 1
Phase connection 2 2
Overvoltage category in accordance with
UL1741
IV IV
AC output, secure power supply operation
Maximum AC power 2000W
Nominal AC voltage 120V
AC voltage range 109V to 132V
Maximum output current 16A
Minimum load 1 W
Multifunction relay
Maximum DC switching voltage 30V
Maximum AC switching current 1.0A
Maximum DC switching current 1.0A
Minimum load 0.1W
Minimum electrical endurance when the maxi-
mum switching voltage and maximum switching
current are complied with*
100000 switching cycles
* Corresponds to 20years at 12switching operations per day
Triggering thresholds and tripping time
Rated power fre-
quency
Triggering threshold Triggering frequency Tripping time
60 Hz >60.5 Hz 60.45Hz to 60.55Hz max. 0.1602 s
<57Hz to 59.8Hz
(Standard: 59.3Hz)
56.95Hz to 59.85Hz
(Standard: 59.25Hz
to 59.35Hz)
Adjustable: 0.16s to
300s
(Standard: max.
0.1602s)
<57.0 Hz 56.95 Hz to 57.05 Hz max. 0.1602s
10 Technical Data
SMA Solar Technology America LLC
Installation manualSB5.0-6.0-1SP-US-40-IA-xx-1062