Use and Care Guide

PLEASE CALL CUSTOMER CARE BEFORE RETURNING ITEM TO LOWE’S: 1-888-755-4497
EN
5
Step 5. Reassemble all pump
parts, place pump back in the
shell, and lock. Reconnect all
tubing and adapters. Place in
water before reconnecting to
the power source.
Step 4. Use a soft cloth or brush and warm
water to clean the impeller, the inside of the
impeller housing and rotor housing.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
Check to make sure the power cord is plugged in and the pump is
getting power.
Check the pump outlet and any tubing, nozzles, spitters etc. for kinks
or obstructions.
Unlatch the clamps, open cover then bring the pump out. Remove the
impeller housing to expose the impeller. Turn the impeller to ensure
that it is not broken or jammed.
IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY
OR THE PUMP DOES NOT FLOW EVENLY:
Check to make sure the pump is completely submerged in water.
Check to make sure the shell, impeller, and the housing are clean.
Adjust ow control.