Installation Guide

TRIM & FASCIA 190, 440, 540 & 2000 SERIES
PREPARATION
• Properly installed ashing materials will help direct water away
from common water collecting areas.
• All ashing material shall be metal or another durable material
that under normal outdoor environmental conditions will last for
a period of not less than 50 years.
All ashing materials must have a minimum 4 inch upper leg.
Add a 4 inch wide adhesive ashing to ashing legs less than
4 inches.
• Properly integrate ashing with the secondary WRB. Use
housewrap, ashing tape, kick-out ashing, step ashing,
Z-ashing, drip edge, gutters or other items as needed to
maintain the counter-ashing principle.
• Install kick-out ashing to direct the water into the gutter.
(See diagram 3a)
• Install step ashing that has a minimum 4 inch upper leg.
(See diagram 3a)
• Maintain a minimum 1 inch clearance between the end of the
gutter and the adjoining wall to allow for proper maintenance of
the siding. (See diagram 3b)
Do not extend the siding or trim into the kick-out ashing or
gutter.
• Prime and paint ALL exposed cut edges of siding and trim.
GENERAL REQUIREMENTS (CONTINUED)
FASTENERS: Minimum 8d (0.113 inch diameter shank), hot-dipped galvanized or stainless steel nail with a 0.270 inch
diameter head. Apply and treat nailing errors as specied by these instructions. (See diagram 3c)
SEALANT: Use an exterior-quality, non-hardening, paintable sealant. Use Class 25 or higher exterior sealant meeting the
ASTM C920 Standard for Specication for Elastomeric Joint Sealants. Follow the sealant manufacturers instructions for
application.
PAINT: Exterior-quality 100% acrylic latex paint, specially formulated for use on wood and engineered wood substrates, is
highly recommended. Semi-gloss or satin nish oil or alkyd paints are acceptable. For at alkyd paint, please check with the
coating manufacturer for their recommendations for use on composite wood siding.
3a
CUTTING
3b
3c
1” min.
clearance
Water Run-O Control
General Application Equipment
WRB
Kick-out
Flashing
4” min.
step-ashing
1” min.
clearance
CONDITION
Snug
Flush
Visible Fiber
Countersunk
1/16 - 1/8 inch
Countersunk
more than 1/8 inch
CORRECTION
OK
OK
Paint
Apply Sealant
Apply Sealant and
re-nail
Shank Diameter ≥ 0.113” Head Diameter ≥ 0.270”
LP SmartSide Trim & Fascia