Doc. No.
Doc. No. SF∗-OMZ0013-A Contents Page 1. Safety Instructions 5 2. Specifications 8 3. How to Order 9 4. Component name and spare parts list 9 5. Replacement of the element 10 6.
Doc. No. SF∗-OMZ0013-A Bacteria Removal Filter Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1) , and other safety regulations. ∗1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.
Doc. No. SF∗-OMZ0013-A Bacteria Removal Filter Safety Instructions Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Doc. No. SF∗-OMZ0013-A 1. Operation Precautions Selection/Caution on Design Do not select a model exceeding specification ranges and carefully consider the purpose of use, required specifications, and operating conditions, such as fluid, pressure, flow rate, nominal filtration rating, and environment. Incorrect handling can result in unexpected accidents. Refer to "Air Preparation Equipment/Precautions" which can be found under "Handling Precautions for SMC Products" in the catalog or on SMC website.
Doc. No. SF∗-OMZ0013-A Operating Environment Warning 1. Do not operate under the conditions listed below due to a risk of malfunction.
Doc. No. SF∗-OMZ0013-A Maintenance Warning Perform maintenance and inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction or damage of machinery and equipment may occur. 1. When removing the product, exhaust the air and ensure the air is released to atmosphere before removing it. 2. When the element comes to the end of its life, immediately replace it with a new filter or replacement element.
Doc. No. SF∗-OMZ0013-A 2. Specifications Port size Rc1/4, NPT1/4, G1/4, Rc3/8, NPT3/8, G3/8 Fluid Air, Nitrogen, Carbon dioxide gas(gas) Rated flow 500L/min (ANR)*1 Nominal filtration rating*2 0.01μm (99.99%)*5 Operating pressure range*3 -100kPa to 1.0MPa (For nitrogen, Carbon dioxide gas: 0.99MPa) 5 to 45oC Operating temperature Initial pressure drop 0.03MPa(Inlet pressure 0.7MPa, at max. flow rate) Element proof differential pressure*4 0.5MPa Proof pressure 1.
Doc. No. SF∗-OMZ0013-A 3. How to Order SFDA203- ∗ ∗ Symbol Thread type Symbol Port size Nil Rc 02 1/4 F G 03 3/8 N NPT 4. Component name and spare parts list Replacement Parts Description Part no.
Doc. No. SF∗-OMZ0013-A 5. Replacement of the element 5-1. Stop Stop operation and reduce the filter’s internal pressure to atmosphere. 5-2. Removal of the cover Hold the flats of the cover and case with a wrench and unscrew. * It is possible that the element comes out together with the cover. In this case, step 5-3 is not necessary. 5-3. Removal of the element Remove the element from the case. 5-4. Mount the element Mount the new element to the cover and insert into the case.
Doc. No. SF∗-OMZ0013-A 6.
Doc. No. SF∗-OMZ0013-A Revision history Rev. A : September, 2021 Add Carbon dioxide gas(gas) Delete Lubrication oil 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.