SDS

SodaStream Carbon Dioxide cylinder.
Issue: 19
Issue date: January 2022 Page 4 of 8
Safety Data Sheet in accordance with
HCS 29cfr1910.1200(g) & WHMIS
2015
SECTION 8: Exposure controls/personal protection
Control parameters
Exposure limit value
Exposure Limit
Component
Result
ACGIH Canada
Ontario
Canada
Quebec
NIOSH OSHA
Carbon
Dioxide
STEL
30000 ppm
STEL
30000 ppm
STEL
30000 ppm
STEL
54000 mg/m
3
STEV
30000 ppm
STEL
54000 mg/m
3
STEL
Not
established
TWA
5000 ppm
TWA
5000 ppm
TWA
5000 ppm
TWA
9000 mg/m
3
TWAEV
5000 ppm
TWA
9000 mg/m
3
TWA
5000 ppm
TWA
9000 mg/m
3
TWA
Exposure controls
Appropriate engineering controls Ensure adequate natural or forced
ventilation.
Personal Protective Equipment Use a NIOSH/MSHA or European standard EN 149
approved respirator if exposure limits are exceeded or inadequate
ventilation is apparent. Wear eye and feet protection. Wear leather or
insulated neoprene gloves when handling cylinders.
SECTION 9: Physical and chemical properties
Information on basic physical and chemical properties
General information
Physical state at 20°C: Liquefied gas in a cylinder, gas when not pressurised.
Appearance/Colour: Colourless liquid or gas.
Odour: No odour warning properties. Some may detect a pungent odour and
biting taste.
Odour threshold Not applicable
pH 3.7 as carbonic acid
Melting point: -70°F (-56,6 °C)
Boiling point: -109,3°F (-78,5 °C)
Sublimation point: -109,3°F (-78,5 °C)
Critical temperature: 86°F (30°)C
Flash point: Not applicable.
Flammability: Non flammable.
Evaporation rate High
Vapour Pressure 20°C: 57,3 bar
Relative density, gas: [air=1] 1,52
Relative density, liquid: [water=1] 0,82
Solubility in water: 2000 mg/l
Decomposition temperature Not available
Autoignition temperature: Not applicable.
Explosive properties: Not explosive
Oxidising properties: Not applicable.
Viscosity Not applicable
Other information Gas/vapour heavier than air. May accumulate in confined spaces, particularly
at or below ground level.
Hazardous decomposition products None