Size 16
MODEL SDBD
DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTER
Motor
HP
RPM
Static Pressure in Inches w.g.
0
0.125 0.25 0.375 0.5 0.625 0.75 0.875 1 1.25 1.5 1.75
1/2
750
CFM
2172 1945
1680 1317 - - - - - - - -
BHP 0.11 0.13 0.13 0.14 - - - - - - - -
Sones 8.6 8.1 7.4 6.7 - - - - - - - -
1/2
800
CFM 2316 2105 1864 1555 - - - - - - - -
BHP 0.13 0.15 0.16 0.17 - - - - - - - -
Sones 9.6 9.1 8.5 7.9 - - - - - - - -
1/2
850
CFM 2461 2263 2039 1776 1424 - - - - - - -
BHP 0.16 0.18 0.19 0.20 0.20 - - - - - - -
Sones 10.6 10.1 9.6 9.1 8.3 - -
- - - - -
1/2 900
CFM 2606 2419 2212 1984 1682 - - - - - - -
BHP 0.19 0.21 0.23 0.23 0.24 - - - - - - -
Sones 11.7 11.2 10.7 10.3 9.5 - - - - - - -
1/2 950
CFM 2751 2574 2383 2175 1913 1590 - - - - - -
BHP 0.22 0.24 0.26 0.27 0.28 0.28 - - - - - -
Sones 12.8 12.4 12.0 11.4 11.0 10.1 - - - - - -
1/2 1000
CFM 2896 2727 2551 2354 2129 1849 - - - - - -
BHP 0.25 0.28 0.30 0.32 0.33 0.33 - - - - - -
Sones 13.9 13.5 13.2 12.7 12.3 11.5 - - - - - -
1/2 1050
CFM 3040 2880 2716
2527 2334 2085 1802 - - - - -
BHP 0.29 0.32 0.34 0.36 0.37 0.38 0.38 - - - - -
Sones 15.1 14.7 14.4 14.0 13.6 13.1 12.1 - - - - -
1/2 1100
CFM 3185 3032 2877 2701 2523 2304 2048 - - - - -
BHP 0.34 0.36 0.39 0.41 0.42 0.44 0.44 - - - - -
Sones 16.4 16.0 15.7 15.3 14.9 14.6 13.7 - - - - -
1/2 1150
CFM 3298 3150 3002 2835 2663 2468 2234 1975 - - - -
BHP 0.37 0.40 0.43 0.45 0.47 0.48 0.49 0.49 - - - -
Sones 17.7 17.3 17.0 16.6 16.3 15.9 15.4 14.3 - - - -
1-1/2 1750
CFM 4984 4896 4804 4705 4601 4493 4383 4271 4155 3911 3636 3305
BHP 1.16
1.20 1.24 1.28 1.32 1.36 1.39 1.42 1.45 1.53 1.59 1.63
Sones 31.7 31.4 31.1 30.9 30.7 30.7 30.4 29.8 29.2 28.1 27.2 26.7
R
®
AIR
MOVEMENT
AND CONTROL
ASSOCIATION
INTERNATIONAL, INC.
AIR
PERFORMANCE
SOUND
and
S&P USA Ventilation Systems, LLC.,
Div. of Soler & Palau Ventilation Group,
certies that the Models RED shown
herein are licensed to bear the AMCA
Seal. The ratings shown are based
on test and procedures performed in
accordance with AMCA Publication
211 and AMCA Publication 311 and
comply with the requirement of the
AMCA Certied Ratings Program.
STANDARD
705
Performance certied is for installation type A-free inlet, free outlet.
Performance ratings include the effects of birdscreen in the airstream.
The sound ratings shown are loudness values in fan sones @ 5' (1.5m) in a hemispherical free eld calculated per AMCA Standard 301. Values shown are for Installation
Type A-free inlet fan sone levels.
Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Fan RPM performances may vary from actual current motor offerings for any given model. See Optisizer2 fan selection software for current motor RPM offerings