Specification Sheet

192
OPTIONS/ACCESSORIES
Solid State Speed Control: S&P’s solid state control is matched to allow smooth RPM variation and
adjustment of airow for system balancing. CFM is reduced in direct proportion to motor speed reduction.
Speed controllers available for 115/1 or 230/1 operation. Exhauster performance can be controlled from
the ventilated area.
Roof Curb: Prefabricated heavy-gauge galvanized steel, welded construction, 12" high (other
heights are also available) with 1-1/2" wood nailer. Assures perfect t of exhauster to roof opening.
Options include burglar bars, single or double pitch construction and hinged curbs for easy duct
access.
Motor Operated Damper: Motor operated aluminum damper for positive closure against backdraft
(Not for UL762 use).
Automatic Damper: Automatic aluminum damper for ease in installation and effective backdraft
protection (Not for UL762 use).
Grease Grabber: Trap designed for fast and inexpensive replacement. Grease collects in a
container for safe and sanitary disposal. Keeps roof clean with proper use.
Wall Mount Kit: Kit allows 6-15" fans to be wall mounted. Assembled as standard on all TXDW units, not available
for not wall mount units. See current submittal for details.
Curb Hinge Arrangement: The curb hinge arrangement provides easy access to the exhaust fan, backdraft
damper, and duct for servicing and cleaning.
Special Coatings: Powered roof exhausters often require special coatings for protective and decorative purposes.
Available coatings include: Synthetic Resin, Epoxy, and Heresite (air-dried phenolic). Contact your representative
or the factory for more information on available coatings and colors.
MODEL TXD