Specification Sheet

29
MODEL SWF
SIDEWALL CENTRIFUGAL FAN
Sound
Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to
the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from
the intake source and other random factors. It is generally accepted that remote mounted venting is quieter than standard
(in room) venting.
Model A B C C1 C2 D
SWF-100
13
1/4
337
13
1/4
337
9
228
3
76
2
7/16
62
4
100
SWF-100x
13
1/4
337
13
1/4
337
9
228
3
76
2
7/16
62
4
100
SWF-150
15
1/2
394
13
1/4
337
10
3/16
256
3
76
2
7/16
62
6
150
SWF-150x
15
1/2
394
16
1/16
408
10
254
3
3/16
81
2
7/16
62
6
150
SWF-200
15
1/2
394
16
1/16
408
11
7/16
290
3
3/8
87
2
7/16
62
8
200
Model RPM Volts Frequency Current Watts
CFM vs. Static Pressure (SP) Ins. WG
0” 0.125” 0.25” 0.375” 0.5” 0.75” 1.0” 1.25” 1.5”
SWF-100 2200 120 60 Hz 0.52 A 57 119 106 92 78 64 44 26 - -
SWF-100X 2600 120 60 Hz 0.8 A 90 171 162 152 142 118 90 66 46 28
SWF-150 2600 120 60 Hz 0.8 A 90 235 221 197 181 168 122 81 60 27
SWF-150X 2800 120 60 Hz 1.0 A 115 354 332 310 287 266 230 192 147 96
SWF-200 2800 120 60 Hz 1.0 A 115 416 395 368 341 324 287 233 184 132
C
C1
C2
D
A
B
2 mm
Air Performance
Dimensions in inches/mm
PERFORMANCE/DIMENSIONS
MODEL SWF