Specification Sheet

312
Model LC and Model L2
Size 36
Limits
Panel OD
Square
Min. Wall
Opening
Damper
OD
Approx.
Wt
Model RPM
Motor
Frame
LC 695 145T 42 43 1/2 40 1/2 105
L2 845 184T 42 43 1/2 40 1/2 215
Size
Motor
HP
Max
BHP
Fan
RPM
Sones
(0.00” SP)
Static Pressure (Inches W.G)
.000 .100 .125 .150 .200 .250 .300 .375 .500 .625 .750
Level 1 Construction
Model LC 36
1/3
0.33 360 8.5 9927 7580 6735 5537 - - - - - - -
0.35 370 8.9 10203 7973 7153 6222 - - - - - - -
0.41 390 9.7 10755 8745 7976 7190 - - - - - - -
1/2
0.50 415 10.8 11444 9631 8967 8237 6333 - - - - - -
0.55 430 11.5 11858 10126 9550 8849 7340 - - - - - -
0.59 440 11.9 12133 10449 9923 9248 7840 - - - - - -
3/4
0.75 475 13.7 13098 11556 11133 10611 9337 7872 - - - - -
0.82 490 14.5 13512 12022 11620 11162 9954 8675 -
- - - -
0.90 505 15.3 13926 12485 12100 11686 10557 9348 7384 - - - -
1
1.00 525 16.4 14477 13103 12731 12348 11345 10187 8897 - - - -
1.09 540 17.3 14891 13562 13199 12834 11930 10809 9653 - - - -
1.19 555 18.1 15305 14018 13663 13312 12495 11419 10317 - - - -
1 1/2
1.50 600 20 16545 15373 15048 14720 14055 13195 12186 10619 - - -
1.58 610 21 16821 15671 15353 15029 14381 13577 12590 11076 - - -
1.79 635 22 17511 16413 16111 15801 15186 14497 13578 12146 - - -
2
2.00 655 23 18062 17003 16713 16415 15819 15189 14366 12975 9909 - -
2.22 680 24 18751 17737 17461 17177 16600 16014 15313 13996 11612 - -
2.37
695 25 19165 18176 17907 17631 17065 16499 15859 14594 12363 - -
Level 2 Construction
Model L2 36
1/2
0.49 410 11.5 10401 9012 8530 7939 6101 3751 2429 - - - -
0.52 420 11.9 10655 9315 8862 8318 6704 4304 2801 - - - -
0.56 430 12.4 10908 9615 9187 8682 7248 4924 3207 - - - -
3/4
0.74 470 14.5 11923 10781 10428 10030 9033 7519 5326 3148 - - -
0.83 490 15.6 12430 11349 11024 10663 9790 8565 6673 3997 - - -
0.88 500 16.1 12684 11631 11317 10971 10148 9030 7335 4483 - - -
1
1.02 520 17.3 13191 12189 11896 11578 10836 9880 8524 5609 2815 - -
1.12 540 18.5 13699 12742 12467 12171 11495 10656 9537 6926 3530 - -
1.17 550 19.1 13952
13017 12750 12464 11815 11024 9994 7606 3926 - -
1.5
1.48 590 22 14967 14106 13867 13613 13054 12403 11615 9987 5858 3443 -
1.60 610 23 15474 14646 14418 14178 13654 13053 12345 10952 7086 4191 -
1.83 630 24 15982 15183 14966 14738 14243 13685 13040 11820 8438 5041 3220
2
1.97 650 25 16489 15718 15510 15292 14824 14302 13708 12619 9756 6021 3903
2.12 670 27 16997 16251 16051 15843 15399 14907 14356 13370 10932 7161 4662
2.30 690 28 17504 16782 16590 16391 15967 15502 14987 14084 11969 8455 5516
3
2.84 740 31 18772 18102 17927 17746 17366 16956 16511 15758 14158 11709 8221
3.14 765 33 19407 18759 18592 18419 18057 17669 17251 16554 15119 13062 9885
3.53 795 35 20168 19546 19386 19222 18879 18514
18125 17483 16202 14476 11880
5
4.86 890 43 22578 22023 21883 21741 21447 21139 20816 20298 19323 18155 16676
5.33 920 46 23339 22801 22667 22531 22249 21955 21648 21158 20249 19182 17876
5.66 940 48 23846 23320 23189 23056 22782 22497 22199 21727 20856 19845 18631
R
®
AIR
MOVEMENT
AND CONTROL
ASSOCIATION
INTERNATIONAL, INC.
AIR
PERFORMANCE
SOUND
and
S&P USA Ventilation Systems, LLC., Div.
of Soler & Palau Ventilation Group, certies
that the models shown herein are licensed to
bear the AMCA Seal. The ratings shown are
based on test and procedures performed in
accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the
requirement of the AMCA Certied Ratings
Program.
Performance ratings do not include the effects of appurtenances (accessories).
Power ratings (BHP) do not include transmission losses.
Performance certied is for installation type A-free inlet, free outlet.
The sound ratings shown are loudness values in fan sones @ 5' (1.5m) in a hemispherical free eld calculated per AMCA Standard 301. Values
shown are for installation Type A-Free inlet fan sone levels.
Due to air stream cooling, the motor loading into the service factor shown does not overheat the motor and is within NEMA recommended limits.
BHP at most static pressure points is less than the maximum power shown - in many cases substantially less. Use Optisizer to see the exact
BHP for your selection.
Standard 705
(Optional)
Standard 705
(Optional)
LC: L2:
MODELS LCE/LCS, L2E/L2S, L3E/L3S
BELT DRIVE SIDEWALL PROPELLER FANS