Specification Sheet

314
Model LC, Model L2 and Model L3
Size 48
Limits
Panel OD
Square
Min. Wall
Opening
Damper
OD
Approx.
Wt
Model RPM
Motor
Frame
LC 455 145T 54 55 1/2 52 1/2 125
L2 605 184T 54 55 1/2 52 1/2 300
L3 765 215T 54 55 1/2 52 1/2 330
Size
Motor
HP
Max
BHP
Fan
RPM
Sones
(0.10” SP)
Static Pressure (Inches W.G)
.000 .100 .125 .150 .200 .250 .300 .375 .500 .625 .750
Level 1 Construction
Model LC 48
1/2
0.50 270 9.5 16739 11961 9933 - - - - - - - -
0.56 280 9.7 17359 12936 11133 6659 - - - - - - -
0.62 290 10.0 17979 13841 12199 10077 - - - - - - -
3/4
0.69 300 10.4 18599 14684 13193 11413 - - - - - - -
0.75 310 10.9 19219 15459 14171 12556 - - - - - - -
0.83 320 11.6 19839 16210 15101 13600 - - - - - - -
0.91 330 12.1 20459 16949 15969 14584 10759 - - - - - -
1
1.00 340 12.7 21079 17678 16778 15563 12363 - -
- - - -
1.09 350 13.4 21699 18411 17542 16493 13606 - - - - - -
1.14 355 13.7 22009 18777 17917 16936 14174 - - - - - -
1.23 365 14.3 22629 19504 18659 17784 15243 10868 - - - - -
1 1/2
1.50 390 15.9 24179 21296 20488 19711 17720 15058 - - - - -
1.63 400 16.7 24799 22004 21219 20452 18668 16187 11973 - - - -
1.82 415 17.8 25729 23054 22306 21548 19994 17746 14950 - - - -
2
2.00 430 18.9 26659 24093 23381 22647 21217 19215 16819 - - - -
2.16 440 19.6 27279 24779 24091 23377 21983 20194 17929 - - - -
2.39 455 21 28209 25800 25148 24463 23107 21574 19479 15382 - - -
Level 2 Construction
Model L2 48
1/2
0.51 265 8.9 14897 11015 9603 7178 - - - - - - -
0.55 270 9.1 15178 11448 10050 8090 - - - - - - -
0.60 280 9.3 15740 12285 10907 9442 - - - - - - -
3/4
0.69 295 10.1 16584 13462 12204 10941 - - - - - - -
0.75 300 10.4 16865 13840 12639 11376 7002 - - - - - -
0.82 310 11.2 17427 14578 13485 12223 9041 - - - - - -
0.90 320 11.9 17989 15300 14290 13092 10504 - - - - - -
1
0.93 325 12.2 18270 15656 14681 13530 11096 - - - - - -
1.00 335 13.0 18832 16352 15443 14388 12128 7739 - - - - -
1.13 345 13.8 19394 17033
16183 15213 13014 9825 - - - - -
1.23 355 14.6 19957 17701 16908 16003 13866 11386 - - - - -
1 1/2
1.50 380 16.4 21362 19320 18656 17879 16032 14051 11129 - - - -
1.68 395 17.5 22205 20262 19664 18958 17294 15342 13239 - - - -
1.80 405 18.2 22767 20884 20322 19661 18094 16184 14339 - - - -
2
2.00 420 19.4 23611 21808 21293 20689 19252 17504 15719 - - - -
2.20 430 20 24173 22419 21926 21361 20000 18365 16577 13276 - - -
2.40 445 21 25016 23331 22864 22350 21095 19608 17847 15192 - - -
3
3.00 480 24 26983 25436 25020 24580 23553 22305 20871 18470 12309 - -
3.36 495 25 27827 26331 25932 25514 24564 23402 22080
19734 15092 - -
3.62 510 27 28670 27222 26838 26439 25556 24479 23245 21054 17098 - -
5
5.00 565 31 31762 30464 30127 29781 29053 28231 27262 25589 22235 18481 -
5.44 585 33 32886 31635 31311 30980 30290 29535 28650 27105 23969 20741 -
6.13 605 35 34010 32802 32491 32174 31516 30811 30001 28571 25707 22582 14450
Level 3 Construction
Model L3 48
7 1/2
7.50 650 40 36540 35419 35132 34841 34243 33616 32945 31753 29362 26441 23603
8.11 670 42 37664 36578 36300 36020 35444 34844 34209 33113 30886 28190 25367
9.05 695 45 39070 38023 37757 37487 36937 36367 35770 34774 32730 30306 27485
10
10.00 720 48 40475 39466 39210 38951 38423 37880 37314 36401 34530 32304 29666
10.88 740 50 41600 40618 40369 40118 39607 39083 38540 37674 35937 33846
31401
12.00 765 52 43005 42056 41816 41574 41083 40580 40061 39243 37651 35714 33496
R
®
AIR
MOVEMENT
AND CONTROL
ASSOCIATION
INTERNATIONAL, INC.
AIR
PERFORMANCE
SOUND
and
S&P USA Ventilation Systems, LLC., Div.
of Soler & Palau Ventilation Group, certies
that the models shown herein are licensed to
bear the AMCA Seal. The ratings shown are
based on test and procedures performed in
accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the
requirement of the AMCA Certied Ratings
Program.
Performance ratings do not include the effects of appurtenances (accessories).
Power ratings (BHP) do not include transmission losses.
Performance certied is for installation type A-free inlet, free outlet.
The sound ratings shown are loudness values in fan sones @ 5' (1.5m) in a hemispherical free eld calculated per AMCA Standard 301. Values
shown are for installation Type A-Free inlet fan sone levels.
Due to air stream cooling, the motor loading into the service factor shown does not overheat the motor and is within NEMA recommended limits.
BHP at most static pressure points is less than the maximum power shown - in many cases substantially less. Use Optisizer to see the exact
BHP for your selection.
Standard 705
(Optional)
Standard 705
(Optional)
LC:
L2 & L3:
MODELS LCE/LCS, L2E/L2S, L3E/L3S