3058080 V.181113 Dehumidifier must be upright for 24 hours prior to operating. This ensures that the compressor will function as intended.
PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Dehumidifier. This Owner’s Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Dehumidifier. For your own records, please attach a copy of your sales receipt to this manual.
DEHUMIDIFIER INFORMATION RECOMMENDED HUMIDITY LEVELS • Spring/Summer: 35% - 45% • Fall/Winter: 45% - 55% WARM AIR EXHAUST IS NORMAL During operation, your dehumidifier will exhaust warm air from the side of the unit. This is normal operation. EMPTYING THE BUCKET The more moisture your dehumidifier removes from the air, the more often you may have to empty the bucket (unless you are using the continuous drainage option). The number of times the bucket will be emptied depends on the dehumidifier model.
PACKAGE CONTENTS (1) Portable Dehumidifier (1) Operating Instructions (4) Casters *Pre-installed on 70 Pint Model SPECIFICATIONS Model Number DS1-30-01 DS1-45E-101 DS1-70E-101 30 Pints per day 45 Pints per day 70 Pints per day 445 Watts 445 Watts 690 Watts 147/129/111 CFM 147/129/111 CFM 205/188/164 CFM Power Source 115 V / 60 Hz 115 V / 60 Hz 115 V / 60 Hz Rated Current (Amps) 2.87 A 4.0 A 6.0 A 53/51/49 dB(A) 53/51/49 dB(A) 53/51/49 dB(A) 31.1 lbs 33.7 lbs 46.
PRODUCT FEATURES Removes up to 30/45/70 pints (depending on model) of moisture from the air every 24 hours. This is not the bucket size. Adjustable humidistat for precise humidity control. Digital humidistat displays set humidity level and current ambient humidity level. Operates at temperatures down to 41°F. Perfect for basement use in the winter. Automatic defrost function melts away ice from frozen coils for continuous, worry-free operation.
CASTER INSTALLATION Caster Installation is only required for the 30 and 45 pint models. (The 70 Pint model includes pre-installed casters.) 1) To install casters on the 30 or 45 pint model, remove the bucket from the dehumidifier. (Fig. 1) 2) Remove and open the box containing the casters from inside the bucket. (Fig. 2) 3) Tilt the dehumidifier no more than 45⁰ and forcibly insert the casters. Make sure the ring around the caster is flush against the bottom of the dehumidifier. (Fig.
OPERATING INSTRUCTIONS Dehumidifier must be upright for 24 hours prior to operating. This ensures that the compressor will function as intended. CONTROL PANEL OPERATING INSTRUCTIONS 1) When first operating the dehumidifier, run it in Continuous mode for 24 hours. 2) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 3) Humidity Selection - Press the or buttons to choose the desired relative humidity in the room.
OPERATING INSTRUCTIONS 8) Bucket Full - When the water bucket completely fills with water, the unit will automatically shut off, make an audible beep, and the Bucket Full Indicator will light up. The dehumidifier will not function until the water bucket is emptied and placed back inside the unit. The bucket should be cleaned every few weeks to prevent the growth of mold, mildew and bacteria. Use a mild detergent to clean the bucket.
CHOOSING A LOCATION A Dehumidifier operating in a basement will have little or no effect in drying out an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. • • • • • • • • • Do not use outdoors. This dehumidifier is intended for indoor use only. Place the dehumidifier on a smooth, level floor surface that is strong enough to support the unit with a full bucket of water. Allow at least 18” of air flow on all sides.
CONTINUOUS DRAINAGE Garden Hose Installation Setup Water can be automatically emptied by attaching a garden hose to the continuous drainage port on the back of the dehumidifier. This will allow the unit to run continuously (depending on the selected humidity level) without having to empty the water bucket. To drain, simply attach a standard garden hose (not included).
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or Replace Filter - The Clean Filter indicator will illuminate every 250 hours of operation as a reminder to clean the filter. A clean filter will keep the unit operating at optimum performance. Remove the filter from the back of the unit by using your thumbs to press down on the filter tabs directly above the filter.
TROUBLESHOOTING Problem Possible Causes Solutions Dehumidifier does not start The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into the outlet. The fuse is blown / circuit break- Check the house fuse / circuit breaker box and replace fuse or er is tripped. reset breaker. Dehumidifier has reached its The dehumidifier automatically turns off when either condipresent level or the bucket is full. tion occurs.
TROUBLESHOOTING Problem Possible Causes Solutions Water on the floor Hose connection may be loose. Check the hose connection. See the CONTINUOUS MODEGARDEN HOSE INSTALLATION AND SET UP Section on Page 10. Hose is attached but not draining Disconnect the hose if using the bucket or place the hose near into a drain. a drain. Unit will not turn on The fuse is blown / circuit break- Check the house fuse / circuit breaker box and replace fuse or er is tripped. reset breaker.
SELF-DIAGNOSING CODES SelfDiagnosing Code Description E1 Compressor Overheat Protection E2 Condenser Overheat Protection EH Humidity Sensor Malfunction Resolution Please call Soleus Customer Service at (877) 665-9765 For any questions or Technical Support, please call customer service (877) 665-9765
LIMITED WARRANTY Three Year Components Limited Warranty Five Year Compressor Limited Warranty Soleus N.A. warrants the accompanying Soleus Air Dehumidifier to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of THREE (3) years for components and FIVE (5) years for the compressor from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus N.A.