Model No. 6G-PAC-10E2 .< 10,000 BTU Portable Air Conditioner Operating Instructions V.
Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
INCLUDE INCLUDE PARTS INCLUDED Window Exhaust Adapter A Adjustable Window Slider (3) Exhaust Hose Power cord Window Exhaust Adapter B Drain hose Window Exhaust Adapter C Hose Clamp Screw (7 ) hook(2) Hose clip(2) Rubber plug RemoWe control Battery (2 ) (AAA.1.5V) Manual SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. Screwdriver(medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 4.
STRUCTURE 1 Front 2 1, Control panel and display lLJKW 2, RemoWe control signal receiver window 3, HandlH 4, Remote controller box 5, Air outlet 6, Vertical louvers 7, Horizontal louvers 8, Wheel 9, Air inlet 10, Grille 11, Air outlet 12,Air inlet 13,Power cord hook 14, Power cord 15, Window exhaust adapter A 16, Exhaust hose 17, Window exhaust adapter B 18, Window exhaust adapter C 19, RemoWe control 3 4 5 6 7 8 Rear 9 10 18 17 15 16 11 19 12 14 13
PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose (1) Window Exhaust Adapter A (1) Window Exhaust Adapter B (1) Window Exhaust Adapter C (1) Remote Control & AAA Batteries (2 batteries) Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) Drain Hose Assembly (drain pipe, hose clamp, hose clip, rubber plug, & screw) Power cord hooks (2hooks & screws) Owner’s Manual SPECIFICATIONS x The cooling capacity is measured at an ambient temperature of DB 95 °F, WB 83 °F.
INSTALLATION OF THE POWER CORD HOOK Attach the hooks to the back of air conditioner with the screws. hook screw Wind the power cord Dround the power cord hooks.
PARTS & WINDOW KIT ASSEMBLY PARTS EXHAUST HOSE & ADAPTERS Exhaust Hose Adapter Exhaust Hose Hose Adapter ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be installed. When the unit is operating in fan mode, the window kit and exhaust hose do not need to be installed . MOUNTING THE EXHAUST HOSE x Choose a suitable location, near a grounded electrical outlet and suitable window or door.
SINGLE HOSE WINDOW KIT INSTALLATION The is a poor installation 26” This installation is OK 22” When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary, use single 90° angles like the pictures above.
CONTROL PANEL DISPLAY & OPERATING INSTRUCTIONS CONTROL PANEL & DISPLAY Temperature selection button LED window COOL mode light Receiver window DRY mode light FAN Speed light ON/OFF button FAN mode light MODE button Fan speed button OPERATING INSTRUCTIONS When pressing key is valid, buzzer makes a sound, indicated light indicates relevant state, system will last for 2 seconds. l. ON/OFF Button Press the button once to manually turn the uni on. Press once more to turn the unit off. 2.
1
REMOTE CONTROL OPERATING INSTRUCTIONS LCD DISPLAY and MODE LABELS NOTE: Heat mode is not available on this unit MODE BUTTON POWER BUTTON TEMP SELECT BUTTONS SWING BUTTON (Not Available on this unit) FAN BUTTON SLEEP BUTTON TIMER BUTTON 1) Power On and Off - Press the ON/OFF (POWER) button once to manually turn the unit on. Press the Power button once more to turn the unit off. When you manually power the unit on and off by pressing the ON/OFF button, the preset timer will be cancelled.
REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.) 5) Auto-on Timer: When the air conditioner is off, it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Timer, press the TIMER button on the unit or remote control. Each touch of the +/buttons on the remote will change the timer setting in 30 minute increments (.5 hours). The T-ON and H lights will blink while the Auto-on Timer is being set.
DRAINING COLLECTED WATER When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is unable to be evaporated is placed in a small bank up water tank inside the unit. When this tank is completely full, an alarm will sound, the compressor will shut off, and the bucket full icon will light up on the control panel. To manually empty the tank, please follow the instructions below.
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged or not x connected well. x Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. x The unit will automatically re-start when power is restored. There is a protective time delay (approx. 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS The LCD Display is showing “E5” Low Voltage Protection x Unplug for 10 minutes and then turn on the unit. If “E5” is still displayed, contact customer service. The LCD Display is showing “H8” The backup water tank is full x x Drain the water tank If the “H8” LV still displayed after the water tank has been emptied, contact customer service.
WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc.